In the standard Exadata Server X11M configuration, the flash riser
board contains an M.2 flash SSD in a socket.
Unpack the replacement M.2 flash SSD and place it on an antistatic mat.
Install the M.2 flash SSD into socket SSD on the flash riser board.
Align and then insert the plastic retainer clip into the slot on the
M.2 flash SSD [1].
Hold the M.2 flash SSD so that the end of the card containing the
plastic retainer clip is approximately one-half to one inch above the
riser board, and the other end is adjacent to the riser SSD socket
[1].
Gently slide the M.2 flash SSD forward and into the connector to
engage the flash SSD contacts with the riser board socket [2].
Using your fingers, push down on the end of the card containing the
plastic retainer clip until the M.2 flash SSD snaps into place on the
riser board [2].
You hear an audible click when the M.2 flash SSD is secured to the
flash riser board.
Perform the steps to install the M.2 flash riser board with the replacement
flash SSD into the server.