Administrative Ethernet Port Cabling Tables RA23

Figure 18-2 shows the cable connections from the servers to the gigabit Ethernet switch in an Oracle Zero Data Loss Recovery Appliance RA23 full rack. The port numbers are the same in racks with fewer storage servers.

The Management Network Switch is located in rack unit 21 on Recovery Appliance RA23. Ethernet cables are blue.

In the following tables, Un denotes the unit height in the rack, where n is the number, such as U20. The cables used for the Management Network Switch are blue in color. Cabling connections marked with * are required for all rack configurations, and represent the minimum rack configuration.

Table 17-2 Ethernet Cabling for the Recovery Appliance RA23 Racks

From Rack Unit(1) Network Management To U21 Ethernet Port Component

U39

NET 0

1

Storage server

U39

NET MGT

2

Storage server

U37

NET 0

3

Storage server

U37

NET MGT

4

Storage server

U35

NET 0

5

Storage server

U35

NET MGT

6

Storage server

U33

NET 0

7

Storage server

U33

NET MGT

8

Storage server

U31

NET 0

9

Storage server

U31

NET MGT

10

Storage server

U29

NET 0

11

Storage server

U29

NET MGT

12

Storage server

U27

NET 0

13

Storage server

U27

NET MGT

14

Storage server

U41

NET 0

15

Storage server

U41

NET MGT

16

Storage server

U25

NET 0

17

Storage server

U25

NET MGT

18

Storage server

PDU A*

NET MGT

19

PDU B*

NET MGT

20

U23

NET 0

21

Storage server

U23

NET MGT

22

Storage server

U18

NET 0

25

Storage server

U18

NET MGT

26

Storage server

U16*

NET 0

29

Compute server

U16*

NET MGT

30

Compute server

U14*

NET 0

31

Compute server

U14*

NET MGT

32

Compute server

U12

NET 0

33

Storage server

U12

NET MGT

34

Storage server

U10

NET 0

35

Storage server

U10

NET MGT

36

Storage server

U08

NET 0

37

Storage server

U08

NET MGT

38

Storage server

U06*

NET 0

39

Storage server

U06*

NET MGT

40

Storage server

U04*

NET 0

41

Storage server

U04*

NET MGT

42

Storage server

U02*

NET 0

43

Storage server

U02*

NET MGT

44

Storage server

U22*

NET MGT 0

45

RDMA Network Fabric switch

U20*

NET MGT 0

46

RDMA Network Fabric switch

U01*

NET MGT 0

47

External

48

Footnote 1 Un is the unit location in the rack, where n is the number.

* These marked components are required for all rack configurations, and together represent the minimum rack configuration.