RDMA Network Fabric Switch-to-Server Cabling Connections RA23

The following tables list the location, ports, and cables for the connections from the RDMA Network Fabric switches to the computer and HC storage servers in a Oracle Zero Data Loss Recovery Appliance RA23 full rack. The port numbers and cable lengths are the same in racks with fewer HC Storage servers. The switches are located in rack units 20 and 22.

All cables are black quad data rate (QDR) cables.

Table 17-6 RDMA Network Fabric Switch to Compute Server Cabling for the Recovery Appliance RA23 Full Racks

From RDMA Network Fabric Switch Rack Unit(1) Port To Rack Unit Device Port Cable Length

U20

22*

U16

2U compute server

PCIe 5, P1

3 meters

U20

23*

U14

2U compute server

PCIe 5, P1

3 meters

U22

22*

U16

2U compute server

PCIe 5, P2

3 meters

U22

23*

U14

2U compute server

PCIe 5, P2

3 meters

Footnote 1 Un is the unit location in the rack, where n is the number.

* All Recovery Appliances have these entries.

Table 17-7 RDMA Network Fabric Switch to HC Server Cabling for the Recovery Appliance RA23 Full Racks

From RDMA Network Fabric Switch Rack Unit(2) RoCE Port To Rack Unit Device Port Cable Length

U20

15

U41

HC Storage server

PCIe 10, P1

3 meters

U20

8

U39

HC Storage server

PCIe 10, P1

3 meters

U20

9

U37

HC Storage server

PCIe 10, P1

3 meters

U20

10

U35

HC Storage server

PCIe 10, P1

3 meters

U20

11

U33

HC Storage server

PCIe 10, P1

3 meters

U20

12

U31

HC Storage server

PCIe 10, P1

2 meters

U20

13

U29

HC Storage server

PCIe 10, P1

2 meters

U20

14

U27

HC Storage server

PCIe 10, P1

2 meters

U20

15

U26

HC Storage server

PCIe 10, P1

2 meters

U20

16

U25

HC Storage server

PCIe 10, P1

2 meters

U20

17

U24

HC Storage server

PCIe 10, P1

2 meters

U20

18

U23

HC Storage server

PCIe 10, P1

2 meters

U20

19

U19

HC Storage server

PCIe 10, P1

2 meters

U20

20

U18

HC Storage server

PCIe 10, P1

2 meters

U20

24

U12

HC Storage server

PCIe 10, P1

2 meters

U20

25

U10

HC Storage server

PCIe 10, P1

2 meters

U20

26

U8

HC Storage server

PCIe 10, P1

2 meters

U20

27

U6

HC Storage server

PCIe 10, P1

2 meters

U20

28

U4

HC Storage server

PCIe 10, P1

2 meters

U20

29

U2

HC Storage server

PCIe 10, P1

2 meters

U20 and U22 should mirror one another

         

U22

15

U41

HC Storage server

PCIe 10, P2

3 meters

U22

8

U39

HC Storage server

PCIe 10, P2

3 meters

U22

9

U37

HC Storage server

PCIe 10, P2

3 meters

U22

10

U35

HC Storage server

PCIe 10, P2

3 meters

U22

11

U33

HC Storage server

PCIe 10, P2

3 meters

U22

12

U31

HC Storage server

PCIe 10, P2

2 meters

U22

13

U29

HC Storage server

PCIe 10, P2

2 meters

U22

14

U27

HC Storage server

PCIe 10, P2

2 meters

U22

15

U26

HC Storage server

PCIe 10, P2

2 meters

U22

16

U25

HC Storage server

PCIe 10, P2

2 meters

U22

17

U24

HC Storage server

PCIe 10, P2

2 meters

U22

18

U23

HC Storage server

PCIe 10, P2

2 meters

U22

19

U19

HC Storage server

PCIe 10, P2

2 meters

U22

20

U18

HC Storage server

PCIe 10, P2

2 meters

U22

24

U12

HC Storage server

PCIe 10, P2

2 meters

U22

25

U10

HC Storage server

PCIe 10, P2

2 meters

U22

25

U10

HC Storage server

PCIe 10, P2

2 meters

U22

26

U8

HC Storage server

PCIe 10, P2

2 meters

U22

27

U6

HC Storage server

PCIe 10, P2

2 meters

U22

28

U4

HC Storage server

PCIe 10, P2

2 meters

U22

29

U2

HC Storage server

PCIe 10, P2

2 meters

Footnote 2 Un is the unit location in the rack, where n is the number.

* All Recovery Appliances have these entries.