The following tables list the location, ports, and cables for the connections from the RDMA Network Fabric switches to the computer and HC storage servers in a Oracle Zero Data Loss Recovery Appliance RA21 full rack. The port numbers and cable lengths are the same in racks with fewer HC Storage servers. The switches are located in rack units 20 and 22.

All cables are black quad data rate (QDR) cables.

Table 18-6 RDMA Network Fabric Switch to Compute Server Cabling for the Recovery Appliance RA21 Full Racks

From RDMA Network Fabric Switch Rack Unit(1) Port To Rack Unit Device Port Cable Length
U20 21* U17 1U compute server PCIe 5, P1 3 meters
U20 22* U16 1U compute server PCIe 5, P1 3 meters
U22 21* U17 1U compute server PCIe 5, P2 3 meters
U22 22* U16 1U compute server PCIe 5, P2 3 meters

Footnote 1 Un is the unit location in the rack, where n is the number.

*All Recovery Appliances have these entries.

Table 18-7 RDMA Network Fabric Switch to HC Server Cabling for the Recovery Appliance RA21 Full Racks

From RDMA Network Fabric Switch Rack Unit(2) Port To Rack Unit Device Port Cable Length
U20 8 U39 HC Storage server PCIe 10, P1 3 meters
U20 9 U37 HC Storage server PCIe 10, P1 3 meters
U20 10 U35 HC Storage server PCIe 10, P1 3 meters
U20 11 U33 HC Storage server PCIe 10, P1 3 meters
U20 12 U31 HC Storage server PCIe 10, P1 2 meters
U20 13 U29 HC Storage server PCIe 10, P1 2 meters
U20 14 U27 HC Storage server PCIe 10, P1 2 meters
U20 15 U26 HC Storage server PCIe 10, P1 2 meters
U20 16 U25 HC Storage server PCIe 10, P1 2 meters
U20 17 U24 HC Storage server PCIe 10, P1 2 meters
U20 18 U23 HC Storage server PCIe 10, P1 2 meters
U20 19 U19 HC Storage server PCIe 10, P1 2 meters
U20 20 U18 HC Storage server PCIe 10, P1 2 meters
U20 23 U14 HC Storage server PCIe 10, P1 2 meters
U20 24 U12 HC Storage server PCIe 10, P1 2 meters
U20 25 U10 HC Storage server PCIe 10, P1 2 meters
U20 and U22 should mirror one another          
U22 8 U39 HC Storage server PCIe 10, P2 3 meters
U22 9 U37 HC Storage server PCIe 10, P2 3 meters
U22 10 U35 HC Storage server PCIe 10, P2 3 meters
U22 11 U33 HC Storage server PCIe 10, P2 3 meters
U22 12 U31 HC Storage server PCIe 10, P2 2 meters
U22 13 U29 HC Storage server PCIe 10, P2 2 meters
U22 14 U27 HC Storage server PCIe 10, P2 2 meters
U22 15 U26 HC Storage server PCIe 10, P2 2 meters
U22 16 U25 HC Storage server PCIe 10, P2 2 meters
U22 17 U24 HC Storage server PCIe 10, P2 2 meters
U22 18 U23 HC Storage server PCIe 10, P2 2 meters
U22 19 U19 HC Storage server PCIe 10, P2 2 meters
U22 20 U18 HC Storage server PCIe 10, P2 2 meters
U22 23 U14 HC Storage server PCIe 10, P2 2 meters
U22 24 U12 HC Storage server PCIe 10, P2 2 meters
U22 25 U10 HC Storage server PCIe 10, P2 2 meters

Footnote 2 Un is the unit location in the rack, where n is the number.