The following table shows the cable connections for the first spine switch (R1-U1) when cabling two full racks together.

Table 24-1 Leaf Switch Connections for the First Rack in a Two-Rack System

Leaf Switch Connection Cable Length
R1 IB3 within Rack 1 R1-IB3-P8A to R1-U1-P3A R1-IB3-P8B to R1-U1-P4A R1-IB3-P9A to R1-U1-P5A R1-IB3-P9B to R1-U1-P6A 3 meters
R1 IB3 to Rack 2 R1-IB3-P10A to R2-U1-P7A R1-IB3-P10B to R2-U1-P8A R1-IB3-P11A to R2-U1-P9A R1-IB3-P11B to R2-U1-P10A 5 meters
R1 IB2 within Rack 1 R1-IB2-P8A to R1-U1-P3B R1-IB2-P8B to R1-U1-P4B R1-IB2-P9A to R1-U1-P5B R1-IB2-P9B to R1-U1-P6B 3 meters
R1 IB2 to Rack 2 R1-IB2-P10A to R2-U1-P7B R1-IB2-P10B to R2-U1-P8B R1-IB2-P11A to R2-U1-P9B R1-IB2-P11B to R2-U1-P10B 5 meters

The following table shows the cable connections for the second spine switch (R2-U1) when cabling two full racks together.

Table 24-2 Leaf Switch Connections for the Second Rack in a Two-Rack System

Leaf Switch Connection Cable Length
R2 IB3 within Rack 2 R2-IB3-P8A to R2-U1-P3A R2-IB3-P8B to R2-U1-P4A R2-IB3-P9A to R2-U1-P5A R2-IB3-P9B to R2-U1-P6A 3 meters
R2 IB3 to Rack 1 R2-IB3-P10A to R1-U1-P7A R2-IB3-P10B to R1-U1-P8A R2-IB3-P11A to R1-U1-P9A R2-IB3-P11B to R1-U1-P10A 5 meters
R2 IB2 within Rack 2 R2-IB2-P8A to R2-U1-P3B R2-IB2-P8B to R2-U1-P4B R2-IB2-P9A to R2-U1-P5B R2-IB2-P9B to R2-U1-P6B 3 meters
R2 IB2 to Rack 1 R2-IB2-P10A to R1-U1-P7B R2-IB2-P10B to R1-U1-P8B R2-IB2-P11A to R1-U1-P9B R2-IB2-P11B to R1-U1-P10B 5 meters