DIA-50719
Control flow edge "string" references undefined string "string".
- control flow edge id
- node role (from_node or to_node)
- referenced node id
Cause
A control_flow_connections entry targets a node id that is not declared in the Flow’s node list or reference_components map.
Action
Update the Flow definition so every control flow edge references a defined node (from_node or to_node), or add the missing node definition before executing the Flow.