ORA-01207

file is more recent than the control file

Cause

The control file change sequence number in the data file was greater than the number in the control file. This implies that the wrong control file was used for the file named in the accompanying error.

Note: Repeatedly causing this error can make it stop happening without correcting the real problem, as every attempt to open the database will advance the control file change sequence number until it is large enough.


Action

If the control file has just been restored, then ensure the file named in the accompanying error is from a backup taken before the time of the control file backup. Otherwise, use the current control file or do backup control file recovery to make the control file current. Be sure to follow all restrictions on doing a backup control file recovery.