PRVG-13383

There are fewer than the recommended number of voting files in ASM disk group "{0}" of redundancy "{1}". [Expected = "{2}" ; Found = "{3}"].

Cause

The Configuration Verification Utility determined that one or more disks used for voting files in the indicated ASM disk group are offline.


Action

Either

  1. Ensure that the offline disks in the indicated ASM diskgroup are online by using the command 'asmcmd online -G disk group name -D disk name. The command 'asmcmd lsdsk -p -G disk group name' can be used to obtain the status of disks in the indicated ASM disk group.

or

  1. Use the command 'crsctl query css votedsk' to obtain the list of voting files. Add more disks to the indicated ASM disk group to match the specified expectation.