Removing the
Acme Packet 6300/6350 from an Equipment Rack
Removing the
Acme Packet 6300/6350 from an Equipment Rack
To remove the
Acme Packet 6300/6350
from an equipment rack:
Disable the two
power sources to the
Acme Packet 6300/6350.
Remove the two
AC/DC power cords from the power supplies in the back of the system. (There are
no ON/OFF switches on these power supplies).
Remove all power
cables from the
Acme Packet 6300/6350.
Remove and label
all attached network cables, alarm cable, and console cables from their
respective ports on the chassis.
Remove ground cable
from the rear of the
Acme Packet 6300/6350.
Save the hex nuts for later re-installation.
Loosen two thumbscrews securing the
Acme Packet 6300/6350 to
the Rack
Loosen the 2
thumbscrews that secure the
Acme Packet 6300/6350 to
the rack rails. This may require using a #2 Phillips screwdriver.
Thumbscrews Securing the
Acme Packet 6300/6350 to
the Rack
Note:
Beginning in this step, one
person should support the
Acme Packet 6300/6350
from below while the other person removes the system chassis from the equipment
rack.
Pull the
Acme Packet 6300/6350
forward and out of the equipment rack.
Note:
The slides have
a mechanical safety stop about halfway down the slide. To fully remove the
chassis, you must depress the release latch points on the chassis slides.
Lift the
Acme Packet 6300/6350
out of the equipment rack, and move it to an ESD safe location.