Copyright © 2024, Oracle and/or its affiliates.
Field Index SQL Mapping

Class /lock_program

Lock Program Storage Object

Notes

  • This object can be read by anyone.
  • This object can be modified by anyone.
  • This object can be created by anyone.

Links



Field Index

Type Field Name
poid PIN_FLD_POID
timestamp PIN_FLD_CREATED_T
timestamp PIN_FLD_MOD_T
string PIN_FLD_READ_ACCESS
string PIN_FLD_WRITE_ACCESS
string PIN_FLD_CREATE_ACCESS
poid PIN_FLD_ACCOUNT_OBJ
string PIN_FLD_PROGRAM_NAME
string PIN_FLD_HOSTNAME
int PIN_FLD_PID
string PIN_FLD_NAME
string PIN_FLD_DESCR


Field Details

poid PIN_FLD_POID

Object Identifier for an instance of this class. Portal object ids have four pieces of information: database number, class type, sequence id, revision.

Notes

  • System defined on object creation
  • Can be modified only by System

Links


timestamp PIN_FLD_CREATED_T

Time the object was created.

Notes

  • System defined on object creation
  • Can be modified only by System

Links


timestamp PIN_FLD_MOD_T

Time the object was last modified.

Notes

  • System defined on object creation
  • Can be modified only by System

Links


string PIN_FLD_READ_ACCESS

Read Access level for object. Valid values are S(Self), G(Global), L(BrandLineage), B(BrandGroup), A(Ancestral).

Notes

  • System defined on object creation
  • Can be modified only by System
  • Maximum length is 255 bytes

Links


string PIN_FLD_WRITE_ACCESS

Write Access level for object. Valid values are S(Self), G(Global), L(BrandLineage), B(BrandGroup), A(Ancestral).

Notes

  • System defined on object creation
  • Can be modified only by System
  • Maximum length is 255 bytes

Links


string PIN_FLD_CREATE_ACCESS

Create Access level for object. Valid values are O(BrandOwner), R(Root), N(Any).

Notes

  • System defined on object creation
  • Can be modified only by System
  • Maximum length is 255 bytes

Links


poid PIN_FLD_ACCOUNT_OBJ

Link to account object for which this object was created.

Notes

  • Required on object creation
  • Can be modified

Links


string PIN_FLD_PROGRAM_NAME

Program name to lock

Notes

  • Required on object creation
  • Can be modified
  • Maximum length is 64 bytes

Links


string PIN_FLD_HOSTNAME

Host where the lock was last made at

Notes

  • Can be specified on object creation
  • Can be modified
  • Maximum length is 64 bytes

Links


int PIN_FLD_PID

Process ID of where the lock was last made at

Notes

  • Can be specified on object creation
  • Can be modified

Links


string PIN_FLD_NAME

User who the lock was last made by

Notes

  • Can be specified on object creation
  • Can be modified
  • Maximum length is 64 bytes

Links


string PIN_FLD_DESCR

Brief Description about the lock

Notes

  • Can be specified on object creation
  • Can be modified
  • Maximum length is 256 bytes

Links




SQL Mapping


Type Field Name Table Column Name
base-class /lock_program lock_program_t
poid PIN_FLD_POID poid*
timestamp PIN_FLD_CREATED_T created_t
timestamp PIN_FLD_MOD_T mod_t
string PIN_FLD_READ_ACCESS read_access
string PIN_FLD_WRITE_ACCESS wrtie_access
string PIN_FLD_CREATE_ACCESS create_access
poid PIN_FLD_ACCOUNT_OBJ account_obj*
string PIN_FLD_PROGRAM_NAME program_name
string PIN_FLD_HOSTNAME hostname
int PIN_FLD_PID pid
string PIN_FLD_NAME name
string PIN_FLD_DESCR descr
Column names marked with * are actually column prefixes. For poid type fields, the column prefix is used to create the columns poid_id0, poid_db and poid_type if the prefix is "poid". For PIN_FLD_POID in the base table, an additional column named poid_rev is created to hold the poid revision. For buffer fields, two columns are created - one in the containing table and one in the buffer table. For example if the prefix is "buf", then the column name in the buffer table is buffer_buf and the column name in the containing table is buffer_size.