What's New in This Guide
This section introduces the new and updated features for release 25.1.2xx.
Release 25.1.200 - G26971-01, July 2025
- Feature Updates:
- New Features:
- BSF Management Service Pod Congestion Control
- Added the BSF Management Service Pod Congestion Control section to describe the support for BSF Management service pod congestion control.
- Added the
ocbsf_http_congestion_message_reject_total
metrics to BSF Management Service to support pod congestion control in BSF Management service. - Added the details of the following Advanced Settings
keys to BSF Management Service menu in CNC Console:
BSF_MGMT_GET_PCF_BINDING_REQUEST_PRIORITY
BSF_MGMT_POST_PCF_BINDING_REQUEST_PRIORITY
BSF_MGMT_DELETE_PCF_BINDING_REQUEST_PRIORITY
BSF_MGMT_POST_AUDIT_NOTIFY_REQUEST_PRIORITY
BSF_MGMT_DELETE_AUDIT_NOTIFY_REQUEST_PRIORITY
BSF_MGMT_GET_SESSION_VIEWER_PCF_BINDING_REQUEST_PRIORITY
BSF_MGMT_POST_SESSION_VIEWER_DELETE_PCF_BINDING_REQUEST_PRIORITY
BSF_MGMT_DELETE_SESSION_VIEWER_DELETEALL_PCF_BINDING_REQUEST_PRIORITY
- Added the following alerts to List of Alerts to support pod congestion control in BSF Management service:
- BSF Management Service Pod Congestion Control
- New Features:
- Enhancements:
- Diameter Gateway Pod Congestion Control
- Updated the Diameter Gateway Pod Congestion Control to support 5 level of congestion states.
- Updated the Congestion Control Settings menu in CNC Console with Diameter Gateway congestion control configurations.
- Updated the Congestion Control Thresholds menu in CNC Console with Diameter Gateway congestion control resource threshold configurations.
- Updated the Congestion Control Load Shedding Rules menu in CNC Console with Diameter Gateway congestion control discard priorities configurations.
- Added the details of the following advanced settings keys in
Diameter Configuration Settings menu in CNC Console.
CONGESTION_DIAMETER_RESPONSE_CODE
CONGESTION_DIAMETER_VENDOR_ID
- Added the details of the following fields in Diameter Message Priority Profiles menu in CNC Console.
DRMP
OC-Message-Priority
- Stale Binding Deletion Logging Enhancement
- Updated the call flow details in Handling Stale Session in BSF.
- Added Enhanced Logging of BSF Stale Binding Deletion section to describe enhanced logging of BSF stale binding deletion.
- Added or updated the description of the following fields for
Enhanced Logging Configuration in General Settings:
- Log Level for Stale Session Deletions
- Enable UE Identifier Information
- Enable UE Identifier Information in Stale Session Deletion Logic
- Added
BSF_STATE_NON_FUNCTIONAL_CRITICAL
alert to BSF_STATE_NON_FUNCTIONAL_CRITICAL, which is used to trigger an alert when the cnDBTier cluster state is down. - Updated Georedundancy Support with the details of four-site georedundancy deployment.
- Diameter Gateway Pod Congestion Control