4.99 chg-m2pa-tset
Use this command to change M2PA timers in an M2PA timer set. The srcset and tset parameters can be used to copy from one timer set to another.
Note:
The M2PA RFC feature introduces 20 new timer sets. M2PA timer sets created prior to this feature become M2PA Draft 6 timer sets, which are used by the M2PA Draft 6 associations. M2PA RFC associations use the RFC timer sets.Parameters
Note:
All values specified for the timer parameters (t(X)) are in milliseconds.- srctset (optional)
-
The timer set to be copied into the timer set specified by the tset parameter. If this parameter is specified, no other timer values can be specified.
- t1 (optional)
- T1 timer. Alignment timer. The amount of time M2PA waits to receive a Link Status Alignment message from the peer.
- t3 (optional)
- T3 timer. Ready timer. The amount of time after proving that M2PA waits to receive a Link Status Ready message from the peer.
- t4e (optional)
- T4E timer. Emergency proving timer. The amount of time M2PA generates Link Status Proving messages during emergency proving.
- t4n (optional)
- T4N timer. Normal proving timer. The amount of time M2PA generates Link Status Proving messages during normal proving.
- t5 (optional)
- T5 timer. Busy rate timer. The amount of time between sending Link Status Busy messages while the link is in service.
- t6 (optional)
- T6 timer. Remote congestion timer. The amount of time that a congested link will remain in service.
- t7 (optional)
- T7 timer. Excessive acknowledgement delay timer. The maximum amount of time that can pass between transmission of a user data message and receipt of an acknowledgement for that message from the peer. If this timer expires, the link is taken out of service.
- t16 (optional)
- T16 timer. Proving rate timer. The amount of time between sending Link Status Proving messages while T2N or T2E is running.
Note:
The T16 value is given in microseconds.
- t17 (optional)
- T17 timer. Ready rate timer. The amount of time between sending Link Status Ready messages while T3 is running.
Example
chg-m2pa-tset:tset=1:t1=20000
chg-m2pa-tset:tset=1:t1=20000:ver=d6
chg-m2pa-tset:srctset=1:tset=2:ver=rfc
Dependencies
At least one optional parameter must be specified.
The srctset parameter and the tset parameter cannot specify the same timer set name.
The specified timer must be supported for the Draft 6 version of M2PA.
Either a timer value or the srctset parameter must be specified.
Timer value parameters and the SRCTSET parameter cannot be specified together.
Notes
None
Output
chg-m2pa-tset:tset=1:t1=20000:ver=d6
rlghncxa03w 06-01-18 08:16:14 EST EAGLE 34.3.0
CHG-M2PA-TSET: MASP A - COMPLTD
;