4.206 dlt-gserv-data

Use this command to delete translation type, originating point code, or global title address data from the GSERV table. These values are used to determine whether a Send Routing Information (SRI) request should receive G-Port SRI Query for Prepaid Service or normal G-Port SRI service.

Parameters

Note:

See Point Code Formats and Conversion for a detailed description of point code formats, rules for specification, and examples.
gta (optional)
Global title address. This parameter specifies a CgPA global title address.
Range:
1 - 21
opc (optional)
ANSI originating point code with subfields network indicator-network cluster-network cluster member (ni-nc-ncm).
Synonym:
opca
Range:
p-, 000-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

prefix—p-

When chg-sid:pctype=ansi is specified, ni = 000 is not valid.

When chg-sid:pctype=ansi is specified, nc = 000 is not valid if ni = 001-005.

When chg-sid:pctype=ansi is specified, nc = 000 is valid if ni = 006-255.

The point code 000-000-000 is not a valid point code.

opc/opca/opci/opcn/opcn24 (optional)
Originating point code. Use these parameters to specify message transfer part (MTP) originating point codes. 
opci (optional)
ITU international originating point code with subfields zone-area-id.
Range:
s-, p-, ps-, 0-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

prefix—s-, p-, ps

zone—0-7

area—000-255

id—0-7

The point code 0-000-0 is not a valid point code.

opcn (optional)
ITU national originating point code in the format of a 5-digit number (nnnnn); or 2, 3, or 4 numbers (members) separated by dashes (m1-m2-m3-m4) as defined by the chg-stpopts:npcfmti flexible point code option. A group code must be specified when the ITUDUPPC feature is turned on (nnnnn-gc, m1-m2-m3-m4-gc).
Range:
s-, p-, ps-, 0-16383, aa-zz

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

prefix—s-, p-, ps

nnnnn—0-16383

gc—aa-zz

m1-m2-m3-m4—0-14 for each member; values must sum to 14

opcn24 (optional)
24-bit ITU national originating point code with subfields main signaling area-sub signaling area-signaling point (msa-ssa-sp).
Range:
p-, 000-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

prefix—p

msa—000–255

ssa—000–255

sp—000–255

tt (optional)
Translation type. This parameter specifies a called party (CdPA) translation type.
Range: 0 - 255

Example

dlt-gserv-data:tt=26

dlt-gserv-data:opc=1-1-1

dlt-gserv-data:gta=9194605500

Dependencies

The tt, opc/opca/opci/opcn/opcn24, or gta parameter must exist in the GSERV table before this command can be entered.

The system is busy, or the GSERV table is corrupted.

The G-Port SRI Query for Prepaid feature must be enabled before this command can be entered.

Only one of the tt, opc, and gta parameters can be specified in the command.

The G-Port feature must be enabled before this command can be entered.

Output

dlt-gserv-data:tt=26

    mystp 06-07-20 09:04:21 EST  EAGLE 35.2.0
    DLT-GSERV-DATA: MASP A - CMPLTD 
;