4.246 dlt-sccp-serv

Use this command to remove entries from the SCCP Service table. The command may either remove a PC from a group or remove the entire group.

Parameters

serv (mandatory)
The name of the service being deleted.
Range:
gflex
gport
all (optional)
Deletes all point codes from a service.
Range:
yes
pc1 (optional)
ANSI point code with subfields network indicator-network cluster-network cluster member (ni-nc-ncm).
Range:
000-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

When chg-sid:pctype=ansi is specified, ni = 000 is not valid.

When chg-sid:pctype=ansi is specified, nc = 000 is not valid if ni = 001–005.

When chg-sid:pctype=ansi is specified, nc = 000 is valid if ni = 006–255.

The point code 000-000-000 is not a valid point code.

pc1/pca1/pci1/pcn1/pcn241 (optional)
Post GTT-translated point code 1.
pc2 (optional)
ANSI point code with subfields network indicator-network cluster-network cluster member (ni-nc-ncm).
Synonym:
pca2
Range:
000-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

When chg-sid:pctype=ansi is specified, ni = 000 is not valid.

When chg-sid:pctype=ansi is specified, nc = 000 is not valid if ni = 001–005.

When chg-sid:pctype=ansi is specified, nc = 000 is valid if ni = 006–255.

The point code 000-000-000 is not a valid point code.

pc2/pca2/pci2/pcn2/pcn242 (optional)
Post GTT-translated point code 2.
pc3 (optional)
ANSI point code with subfields network indicator-network cluster-network cluster member (ni-nc-ncm).
Synonym:
pca3
Range:
000-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

When chg-sid:pctype=ansi is specified, ni = 000 is not valid.

When chg-sid:pctype=ansi is specified, nc = 000 is not valid if ni = 001–005.

When chg-sid:pctype=ansi is specified, nc = 000 is valid if ni = 006–255.

The point code 000-000-000 is not a valid point code.

pc3/pca3/pci3/pcn3/pcn243 (optional)
Post GTT-translated point code 3.
pc4 (optional)
ANSI point code with subfields network indicator-network cluster-network cluster member (ni-nc-ncm).
Range:
000-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

When chg-sid:pctype=ansi is specified, ni = 000 is not valid.

When chg-sid:pctype=ansi is specified, nc = 000 is not valid if ni = 001–005.

When chg-sid:pctype=ansi is specified, nc = 000 is valid if ni = 006–255.

The point code 000-000-000 is not a valid point code.

pc4/pca4/pci4/pcn4/pcn244 (optional)
Post GTT-translated point code 4.
pci1 (optional)
ITU international point code with subfields zone-area-id. The prefix subfield indicates a spare point code (prefix-zone-area-id).
Range:
s-, 0-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

prefix—s

zone—0-7

area—000-255

id—0-7

The point code 0-000-0 is not a valid point code.

pci2 (optional)
ITU international point code with subfields zone-area-id. The prefix subfield indicates a spare point code (prefix-zone-area-id).
Range:
s-, 0-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

prefix—s

zone—0-7

area—000-255

id—0-7

The point code 0-000-0 is not a valid point code.

pci3 (optional)
ITU international point code with subfields zone-area-id. The prefix subfield indicates a spare point code (prefix-zone-area-id).
Range:
s-, 0-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

prefix—s

zone—0-7

area—000-255

id—0-7

The point code 0-000-0 is not a valid point code.

pci4 (optional)
ITU international point code with subfields zone-area-id. The prefix subfield indicates a spare point code (prefix-zone-area-id).
Range:
s-, 0-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

prefix—s

zone—0-7

area—000-255

id—0-7

The point code 0-000-0 is not a valid point code.

pcn1 (optional)
ITU national point code in the format of a 5-digit number (nnnnn); or 2, 3, or 4 numbers (members) separated by dashes (m1-m2-m3-m4) as defined by the chg-stpopts:npcfmti flexible point code option. A group code must be specified when the ITUDUPPC feature is turned on (nnnnn-gc, m1-m2-m3-m4-gc). The prefix subfield indicates a spare point code (prefix-nnnnn, prefix-nnnnn-gc, prefix-m1-m2-m3-m4, prefix-m1-m2-m3-m4-gc).
Range:
s-, 0-16383, aa-zz

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

prefix—s-

nnnnn—0-16383

gc—aa-zz

m1-m2-m3-m4—0-14 for each member; values must sum to 14

pcn2 (optional)
ITU national point code in the format of a 5-digit number (nnnnn); or 2, 3, or 4 numbers (members) separated by dashes (m1-m2-m3-m4) as defined by the chg-stpopts:npcfmti flexible point code option. A group code must be specified when the ITUDUPPC feature is turned on (nnnnn-gc, m1-m2-m3-m4-gc). The prefix subfield indicates a spare point code (prefix-nnnnn, prefix-nnnnn-gc, prefix-m1-m2-m3-m4, prefix-m1-m2-m3-m4-gc).
Range:
s-, 0-16383, aa-zz

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

prefix—s-

nnnnn—0-16383

gc—aa-zz

m1-m2-m3-m4—0-14 for each member; values must sum to 14

pcn241 (optional)
24-bit ITU national point code with subfields main signaling area-sub signaling area-signaling point (msa-ssa-sp).
Range:
000-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

msa—000–255

ssa—000–255

sp—000–255

pcn242 (optional)
24-bit ITU national point code with subfields main signaling area-sub signaling area-signaling point (msa-ssa-sp).
Range:
000-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

msa—000–255

ssa—000–255

sp—000–255

pcn243 (optional)
24-bit ITU national point code with subfields main signaling area-sub signaling area-signaling point (msa-ssa-sp).
Range:
000-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

msa—000–255

ssa—000–255

sp—000–255

pcn244 (optional)
24-bit ITU national point code with subfields main signaling area-sub signaling area-signaling point (msa-ssa-sp).
Range:
000-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

msa—000–255

ssa—000–255

sp—000–255

pcn3 (optional)
ITU national point code in the format of a 5-digit number (nnnnn); or 2, 3, or 4 numbers (members) separated by dashes (m1-m2-m3-m4) as defined by the chg-stpopts:npcfmti flexible point code option. A group code must be specified when the ITUDUPPC feature is turned on (nnnnn-gc, m1-m2-m3-m4-gc). The prefix subfield indicates a spare point code (prefix-nnnnn, prefix-nnnnn-gc, prefix-m1-m2-m3-m4, prefix-m1-m2-m3-m4-gc).
Range:
s-, 0-16383, aa-zz

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

prefix—s-

nnnnn—0-16383

gc—aa-zz

m1-m2-m3-m4—0-14 for each member; values must sum to 14

pcn4 (optional)
ITU national point code in the format of a 5-digit number (nnnnn); or 2, 3, or 4 numbers (members) separated by dashes (m1-m2-m3-m4) as defined by the chg-stpopts:npcfmti flexible point code option. A group code must be specified when the ITUDUPPC feature is turned on (nnnnn-gc, m1-m2-m3-m4-gc). The prefix subfield indicates a spare point code (prefix-nnnnn, prefix-nnnnn-gc, prefix-m1-m2-m3-m4, prefix-m1-m2-m3-m4-gc).
Range:
s-, 0-16383, aa-zz

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

prefix—s-

nnnnn—0-16383

gc—aa-zz

m1-m2-m3-m4—0-14 for each member; values must sum to 14

Example

To delete a specified PC from the G-Port service:

dlt-sccp-serv:serv=gport:pca2=3-3-3

To delete all PCs from the G-Port service and to specify a network PC to delete:

dlt-sccp-serv:serv=gport:all=yes:pca1=1-1-1

Dependencies

At least one PC must be specified.

The MRN table must be accessible.

The SCCP Service table must be accessible.

The specified PC must already exist in the SCCP Service table.

The same point code cannot be specified more than once.

The specified point code must already exist in the specified MRN set in the SCCP-SERV table.

At least one point code must be specified.

The specified MRN set must already exist in the SCCP-SERV table portion of the MRN table.

Notes

In this command, only ITU-international and ITU national point codes support the spare point code subtype prefix (s-).

Output

dlt-sccp-serv:serv=gport:pca2=3-3-3

    tekelecstp 05-12-20 08:54:59 EST  EAGLE 35.0.0
    DLT-SCCP-SRV: MASP A - COMPLTD 
;

Related Topics