What's New in This Guide
This section introduces the documentation updates for Release 25.2.2xx in Oracle Communications Network Analytics Data Director Diameter User Guide.
Release 25.2.201 - G48765-02, July 2026
- Updated details of "Message Sequencing" in the Overview section.
- Added the following new features in the Features List chapter:
-
- New guidance was added for the default vCollector topic.
- Default Helm-configured vCollector
topicNameis now documented as:VCOLLECTOR-DIAMETER
- New instructions were added for using a different
topicName:- Update
OCNADD_DIAMAGGREGATION_SERVICE_SOURCE_TOPIC. - Create a vCollector topic corresponding to the configured topic name for the relay agent group.
- Update
-
- Added UI-based VCollector Feed management.
- Includes updating a VCollector Feed:
- Interfaces and filter values can be added, removed, or updated.
- Duplicate IP Packet Suppression, SCTP Dechunking, and TCP Flow Management settings can be updated.
- Kafka configuration details can be edited.
- Kafka configurations can be added or removed.
- Includes deleting a VCollector Feed:
- Delete action is available from the VCollector Feed panel.
- Deleted feed details cannot be recovered.
-
- Added limits:
- Maximum Diameter Export configurations supported:
3 - Maximum export conditions in one export filter configuration row:
4 - Maximum values allowed for one export filter condition attribute:
20
- Maximum Diameter Export configurations supported:
- Added limits:
-
Metrics, KPIs, Alerts, and Alarms, Prometheus Service Alerts
- New Prometheus service alerts were added.
- Added alert for Diameter Storage Adapter:
- Alert:
OCNADD_DIAMETER_STORAGEADAPTER_SVC_DOWN - OID:
1.3.6.1.4.1.323.5.3.53.1.49.2002 - Description: Diameter Storage Adapter service not available.
- Alert:
- Added alert for Diameter Export:
- Alert:
OCNADD_DIAMETER_EXPORT_SVC_DOWN - OID:
1.3.6.1.4.1.323.5.3.53.1.39.2002 - Description: Diameter Export service not available.
- Alert:
-
Alarms, Alarm Types
OPERATIONAL_ALARMSrange was updated.- Old range:
5000-5999
- New range:
5000-59999
-
Alarms> Diameter Feature Alarms
- New Diameter-specific alarms table was added.
- New alarms include:
- Diameter Aggregation topic unavailable.
- Diameter Correlation topic unavailable.
- Diameter Storage Adapter topic unavailable.
- Diameter Storage Adapter xDR data send failure to database.
- Diameter Export database unavailable.
- Diameter Export no data available for export.
- Diameter Export SFTP service unreachable.
- Diameter Export file server credential unavailable.
- Diameter Export storage full.
- Diameter Export SFTP write failure.
Release 25.2.200 - G48765-01, December 2025
This is the initial release of this document.