Known Issues
This table lists the OCSBC known issues in version CZ8.2.0. You can reference known issues by Service Request number and you can identify the issue, any workaround, when the issue was found, and when it was fixed using this table. Issues not carried forward in this table from previous Release Notes are not relevant to this release. You can review delivery information, including defect fixes in this release's Build Notes.
ID | Description | Severity | Found In | |
---|---|---|---|---|
None | This version's enhancement to SMP-Aware Task Load Limiting, which adds a second parameter to the sip-config load-limit option, is currently not supported. | N/A | SCZ740 | |
24574252 |
The show interfaces brief command incorrectly shows pri-util-addr information in its output. | 3 | SCZ740 | |
26790731 |
Running
commands with very long output, such as the "show support-info" command, over
an OVM virtual console might cause the system to reboot.
Workaround: You must run the "show support-info" command only over SSH. |
2 | SCZ800 | |
26338219 | The packet-trace remote command does not work with IPv6. | 2 | SCZ740 | |
26497348 |
When operating in HA mode, the OCSBC may display extraneous "Contact ID" output from the show sipd endpoint-ip command. You can safely ignore this output. | 3 | SCZ800 | |
26258705 |
The show sipd srvcc command does not display the correct number of unsuccessful aSRVCC calls. | 3 | SCZ800 | |
26598075 |
When running on the Acme Packet 4600, the OCSBC sends a 200OK with IPv4 media address for call flows with offerless INVITES and the OCSBC configured with add-sdp-invite=invite and ALTC configured for IPv6 on the egress. | 3 | SCZ800 | |
26559988 |
In call flows that include dual ALTC INVITEs from the callee, and subsequent Re-INVITEs that offer an ALTC with IPv6 video, the OCSBC may not include the m lines in the SDP presented to the end stations during the Re-INVITE sequence. This results in the call continuing to support audio, but not video. | 3 | SCZ800 | |
None |
Re-balancing is unavailable on the OCSLB when running an Acme Packet 6300 as a cluster member. Set the SLB cluster-config, auto-rebalance parameter to disabled to use an Acme Packet 6300 as a cluster member from that SLB. | N/A | SCZ730 | |
21805139 |
RADIUS stop records for IWF calls may display inaccurate values. | 2 | SCZ730b6 | |
24809688 |
Media interfaces configured for IPv6, and using different VLANs that operate over different infrastructures, including VoLTE and 3GPP, are not supported. | 3 | SCZ730 | |
None |
The system does not support SIP-H323 hairpin calls with DTMF tone indication interworking. | N/A | S-CZ720 | |
None |
The
OCSBC stops responding
when you configure an H323 stack supporting SIP-H323-SIP calls with the
max-calls parameter
set to a value that is less than the
q931-max-calls
parameter.
Workaround: For applicable environments, configure the H323 stack max-calls parameter to a value that is greater than its q931-max-calls parameter. |
N/A | S-CZ740 | |
None | The system does not support HA Redundancy for H.323 calls. | N/A | N/A | |
23756306 |
When you configure the session-router with an operation-mode of session, it does not correctly clear sessions. |
3 | S-Cz7.2.0 | |
23253731 |
After an HA switchover, the new standby OCSBC retains some IMS-AKA subscriber TCP sockets. You can clear these sockets by rebooting the OCSBC. | 2 | SCZ730M2 | |
27699451 |
Oracle qualified the QSFP interface for the OCSR operating over the Oracle X7-2 platform for a single QSFP port operating in 4-port mode. Specifically, 4 media interfaces successfully map to the second port of the QSFP interface using a Hydra cable as physical connections to 10G switch ports. | 3 | SCZ810 | |
27911939 |
When running the OCSBC over the KVM hypervisor and using SR-IOV interface mode, the system fails over when all of following conditions are in effect:
|
3 | SCZ810 | |
28617938 |
The
anonymize-invite
option for CommMonitor is not RTC. To see a change, you must either reboot or
toggle the admin state. The following is a general admin state toggle
procedure:
|
4 | CZ810m1 | |
28618563 |
The system is not populating the Username AVP in Accounting Requests (ACRs) correctly. When triggered by an INVITE, these AVPs contain only the "@" sign. They do not include the username and domain name portion of the URL. | 3 | CZ810m1 | |
26316821 |
When configured with the 10 second QoS update mechanism for OCOM, the OCSBC presents the same codec on both sides of a transcoding call in the monitoring packets. You can determine the correct codecs from the SDP in the SIP Invite and 200 OK. |
3 | SCZ8.0.0p1 | |
26323802 |
The 10s QoS interim feature includes the wrong source IP address as the incoming side of a call flow. The issue does not prevent successful call and QoS monitoring. For monitoring and debugging purposes, you can find the source IP in the SIP messages (INVITE/200OK). |
3 | SCZ8.0.0p1 | |
26669090 |
The OCSBC dead peer detection does not work with IPv4. | 3 | SCZ8.0.0 | |
27031344 |
When configured to perform SRTP-RTP interworking, the OCSBC might forward SRTP information in the SDP body of packets on the core side, causing the calls to terminate. Workaround: Add an appropriately configured media-sec-policy on the RTP side of the call flow. This policy is in addition to the policy on the SRTP side of the call flow. |
3 | SCZ8.0.0p1 | |
28539155 | When operating as a VNF and using Mellanox interface cards, the OCSBC does not support ICMP over IPv6. | 3 | SCZ820 | |
28539190 | When operating as a VNF and using Mellanox interface cards, the OCSBC does not use the Host In Path (HIP) configuration to restrict management traffic, Instead the system allows any traffic over the interface. | 3 | SCZ820 | |
28617865 | This version of the OCSBC only is not supported as a VNF over VMware using Mellanox interface cards. | 3 | SCZ820 | |
28639227 | When operating as a VNF and using Mellanox interface cards, the OCSBC does not support SCTP transport. | 3 | SCZ820 | |
28658810 | When operating as a VNF and using Mellanox interface cards, the OCSBC does not support any other type of card for media interfaces. (If any media interface uses a Mellanox card, all media interfaces must use a Mellanox card.) | 3 | SCZ820 | |
28748784 | When operating as a VNF and using Mellanox interface cards, the OCSBC does not support outbound ICMP. | 3 | SCZ820 | |
28819431 | For TSM use case, the ETC CPU load increased 40% over the previous release. | 2 | SCZ820 | |
28906914 | For transcoding use cases, the G711/G729 codec pair might experience unstable performance when each DSP has greater than 500 transcoding sessions. | 3 | SCZ820 | |
29005944 | On engineered hardware in an HA configuration, with a large number of IMS-AKA endpoints, the standby is unable to syncronize, and when rebooted goes OOS. | 3 | SCZ820 | |
28999116 | IWF (SIP-H323) appears at the setup entitlements prompt on virtual platforms when H.323 is not supported. | 3 | SCZ820 | |
28770472 | ACLI Users will receive an error on the output of the show registration sipd by-user command. | 4 | SCZ820 | |
29170419 | In long call scenarios, the SBC is not sending the expected refresh before the Session-Expires: header value time is up for SUBSCRIBE messages. | 2 | SCZ820 | |
29322490 | The SBC intermittently does not process the registration (Event: reg) of a SUBSCRIBE with Expires header=0 that should be created after receiving a NOTIFY with a termination request from a UE. | 2 | SCZ820 | |
29931732 |
The embedded communications monitor probe does not send IPv6 traffic to the Oracle Communications Operations Monitor's mediation engine. | 3 | SCZ800 | |
28820258 | On PNF
platforms, when running TLS Chat on VMware-PV 4core (SSFD) + 16GB, TLS Chat
sessions are gradually decreasing. When looking in Wireshark at EXFO, EXFO
forwards a wrong TLS MSRP Chat payload to EXFO UAS.
TCP Chat does not have this error. |
3 | SCZ800 |
Resolved Known Issues
ID | Description | Severity | Found In | Fixed In | |
---|---|---|---|---|---|
29937232 |
GW unreachable and NetBufCtrl MBUFF errors - This can result in system instability including crash, gw-unreachable and redundancy issues. System will switchover if in HA. Show Buffers output will normally show an increase of errors reported in the NetBufCtrl field due to mbuf’s not being freed. |
2 | SCZ820 | SCZ830p6 | |
28679339 |
When supporting SRVCC roaming calls, the OCSBC is handling SRVCC end-station de-registration events by properly including associated URIs in the 200 OK. It is not, however, saving those associated URIs in its registration cache. This causes the OCSBC to respond to calls to those URIs with 404 not found messages until the end-station re-registers. | 2 | SCZ800 | SCZ820p4 | |
28526228 | Maximum SRTP capacity on VNF platforms is 25% lower than in the SCZ8.1.0 release. Expected capacity will be restored in a follow up patch. | 3 | SCZ820 | SCZ830 | |
26313330 |
In some early media call flows, the OCSBC may not present the correct address for RTP causing the call to terminate. | 3 | SCZ800 | SCZ820 | |
26281599 |
The system
feature provided by the
phy-interfaces
overload-protection
parameter and
overload-alarm-threshold
sub-element is not functional. Specifically, enabling the protection and
setting the thresholds does not result in trap and trap-clear events based on
the interface's traffic load.
The applicable ap-smgmt.mib SNMP objects include:
|
3 | SCZ720 | SCZ820 | |
25144010 |
When an OCSBC operating on an Acme Packet 6300 fails over, the secondary can successfully add new ACL entries, but it also retains old ACL entries that it should have deleted. | 3 | SCZ740p1 |
SCZ820 |
|
26183767 |
When operating in HA mode and handling large traffic loads, the active OCSBC stops responding when you restore large configurations that are different from the configuration the active is currently running. The system subsequently goes out of service. | 3 | SCZ800 |
SCZ820 |
|
21975038 | The Acme Packet 4600, 6100, 6300, and 6350 platforms do not support MSRP File Transfer. | 3 | SCZ810 | SCZ820 | |
27579686 | This release does not support TSM. | 2 | SCZ810 | SCZ820 | |
27539750 |
When trying to establish a connection between the SBC and your network, while using TLS version 1.2, the SBC may reject the connection. Workaround: You may need to adjust your cipher list. |
3 | SCZ810 | SCZ810 | |
28062411 | Calls that require SIP/PRACK interworking as invoked by the 100rel-interworking option on a SIP interface do not work in pooled transcoding architectures. | 2 | SCZ740 | SCZ820 | |
28071326 | Calls that require LMSD interworking, as invoked by the lmsd-interworking option on a SIP interface, do not work in pooled transcoding architectures. During call establishment, when sending the 200 OK back to the original caller, the cached SDP is not included. | 2 | SCZ740 | SCZ820 | |
None | The CZ8.1.0
release does not support IPSec on the Acme Packet 3900 and VNF. You must
upgrade to CZ8.1.0p1 to get this support. After you upgrade to CZ8.1.0p1, do
the following:
|
N/A | CZ810 | CZ820 | |
28305575 | On VNFs, the system erroneously displays the IPSEC entitlement under "Keyed (Licensed) Entitlements." The error does not affect any functionality and you do not need to do anything. | 4 | CZ810 | CZ820 | |
28659469 |
When booting
CZ8.1.0M1 on any virtual platform, not all system processes start. This known
issue only occurs on initial boot, and not in an upgrade scenario.
Workaround: Reboot the OCSBC a second time, after it initially starts. |
3 | CZ810m1 | SCZ820 | |
If you configured the ims_aka option, you must also configure sip-interfaces with an ims-aka-profile entry. | 3 | ECZ7.4.0 | ECZ7.4.0m1 | ||
28998693 | For TSM use cases, AP6100 and AP6300 systems do not support data-flow modes. | 2 | SCZ820 | SCZ820p1 | |
27811129 |
When upgrading an OCSBC from a version that uses License Keys to enable CODECs, you must reboot the system after setting any CODEC entitlements to override the License Keys. | 3 | SCZ810 | SCZ820 |
ID | Description | Found In | Fixed In |
---|---|---|---|
22322673 |
When running in an HA configuration, the
secondary
OCSBC might go out of
service (OoS) during upgrades, switchovers, and other HA processes while
transitioning from the "Becoming Standby" state. Oracle observes such behavior
in approximately 25% of these circumstances. You can verify the issue with
log.berpd, which can indicate that the media did not synchronize.
Workaround: Reboot the secondary until it successfully reaches the "Standby" state. |
N/A | N/A |
N/A | The T.140-Baudot Relay is not excluded from supported features with pooled transcoding. | N/A | N/A |
28367500 |
When operating the OCSBC on the Acme Packet 6300, the traceroute command does not show hops for an IPv6 traceroute that does not reach the target address. The system successfully displays hops when the traceroute reaches the target and for IPv4 traceroutes. | N/A | N/A |