Environment Monitor MIB (ap-env-monitor.mib)
The following table describes the SNMP GET query names for the Environment Monitor MIB (ap-env-monitor.mib).
SNMP GET Query Name | Object ID: 1.3.6.1.4.1.9148.3.3.1 + | Description |
---|---|---|
apEnvMonI2CState | .1 | State of the environmental monitor located in
the chassis. Values are:
initial (1): environment is at the initial state normal (2): environment is good; for example at low temperature minor (3): environment is not good; for example fans speed is more than minor alarm threshold but less than major alarm threshold major (4): environment is bad; for example an speed is more than major alarm threshold, but less than critical alarm threshold critical (5): environment is very bad; for example fan speed is more than critical alarm threshold shutdown (6): environment is at its worst, the system should be shutdown immediately notPresent (7): environmental monitor is not present notFunctioning (8): environmental monitor does not function properly; for example, IC2 failure or temperature sensor generates abnormal data unknown (9): no information available because of internal error |
The apEnvMonVoltageStatusEntry object has the OID 1.3.6.1.4.1.9148.3.3.1.2.1.1. This object is deprecated.
The apEnvMonTemperatureStatusEntry object has the OID 1.3.6.1.4.1.9148.3.3.1.3.1.1.
SNMP GET Query Name | Object ID: 1.3.6.1.4.1.9148.3.3.1.3.1.1 + | Description |
---|---|---|
apEnvMonTemperatureStatusType | .2 | Indicates the entity being monitored for
temperature. Values are:
ds1624sMain (1) ds1624sCPU (2) lm84 (3) lm75 (4) lm75Main (5) lm75Cpu (6) lm75Phy (7) |
apEnvMonTemperatureStatusDescr | .3 | Description of the temperature being monitored. It has the value of the Main Board PROM Temperature (in Celsius). |
apEnvMonTemperatureStatusValue | .4 | The current temperature of the main board PROM in Celsius. |
apEnvMonTemperatureState | .5 | Current state of the temperature which can have
one of the following values:
3800: 1: initial. Temperature is at its initial state. 2: normal. The temperature is normal. 3: minor alarm - the temperature is greater than or equal to 53 degrees Celsius and less than 63 degrees Celsius. 4: major alarm. The temperature is greater than or equal to 63 degrees Celsius and less than 73 degrees Celsius. 5: critical alarm. The temperature is greater than 73 degrees Celsius. 6: shutdown. The system should be shutdown immediately 7: not present: The temperature sensor does not exist. 8: not functioning: The temperature sensor is not functioning properly. 9: unknown. Cannot obtain information due to an internal error. 4500: 1: initial. Temperature is at its initial state. 2: normal. The temperature is normal. 3: minor alarm - the temperature is greater than or equal to 95 degrees Celsius and less than 100 degrees Celsius. 4: major alarm. The temperature is greater than or equal to 100 degrees Celsius and less than 105 degrees Celsius. 5: critical alarm. The temperature is greater than or equal to 105 degrees Celsius. 6: shutdown. The system should be shutdown immediately 7: not present: The temperature sensor does not exist. 8: not functioning: The temperature sensor is not functioning properly. 9: unknown. Cannot obtain information due to an internal error. |
apEnvMonTemperatureSlotID | .6 | Slot for which this temperature is found. |
apEnvMonTemperatureSlotType | .7 | Type of module found in this slot. |
The apEnvMonFanStatusEntry object has the OID 1.3.6.1.4.1.9148.3.3.1.4.1.1.
SNMP GET Query Name | Object ID: 1.3.6.1.4.1.9148.3.3.1.4.1.1 + | Description |
---|---|---|
apEnvMonFanStatusType | .2 | Location of the fan, which can have one of the
following values:
11: fan1 12: fan2 13: fan3 14: fan4 |
apEnvMonFanStatusDescr | .3 | Textual description of the fan. |
apEnvMonFanStatusValue | .4 | Current measurement of fan speed in percentage. |
apEnvMonFanState | .5 | Current state of the fan speed which can have
one of the following values:
1: initial. The temperature is at its initial state. 2: normal. The fan speed is normal. 3: minor. The fan speed is between 75% and 90% of the full fan speed 4: major. The fan speed is between 50% and 75% of the full fan speed 5: critical. The fan speed is less than 50% of the full fan speed. 6: shutdown. The system should be shutdown immediately 7: not present. The fan sensor does not exist. 8: not functioning. The fan sensor is not functioning properly. 9: unknown. Cannot obtain information due to an internal error. |
apEnvMonFanState | .6 | Current state of the fan being monitored. |
apEnvMonFanSlotID | .7 | Slot where this fan is found. A zero is returned if this fan is not the type slot. |
The apEnvMonPowerSupplyStatusEntr object has the OID 1.3.6.1.4.1.9148.3.3.1.5.1.1.
SNMP GET Query Name | Object ID: 1.3.6.1.4.1.9148.3.3.1.5.1.1 + | Description |
---|---|---|
apEnvMonPowerSupplyStatusType | .2 | Location of the power supply, which can have
one of the following values:
0: left power supply B 1: right power supply A 3: slot |
apEnvMonPowerSupplyStatusDescr | .3 | Textual description of the power supply. |
apEnvMonPowerSupplyState | .4 | Current state of the power supply. Values:
2: normal. The power supply is normal. 7: not present: The power supply sensor does not exist. |
The apEnvPhyCardStatusEntry object has the OID 1.3.6.1.4.1.9148.3.3.1.6.1.1.
SNMP GET Query Name | Object ID: 1.3.6.1.4.1.9148.3.3.1.6.1.1 + | Description |
---|---|---|
apEnvMonPhyCardStatusDescr | .3 | Textual description of the phy card. |
apEnvMonPhyCardState | .4 | The current state of the phy card. Values:
2: normal 7: not present |