data-flow
The data-flow configuration element specifies pass-through data-traffic processing when using IKE.
Parameters
- name
 - Specify the name of this instance of the data-flow configuration element.
 - realm-id
 - Specify the realm that supports the upstream (core side) data-flow.
 - group-size
 - 
                        						
                        Specify the maximum number of user elements grouped together by this data-flow instance. For maximum efficiency, this value should be set to a power of 2.
- Default: 128
 - Values: 1 | 2 | 4 | 8 | 16 | 32 | 64 | 128 | 256
 
Note:
The optional group-size parameter specifies the divisor used by this data-flow instance to segment the total address pool into smaller, individually-policed segments. - upstream-rate
 - Specify the allocated upstream bandwidth. 
                        
- Default: 0 (allocates all available bandwidth)
 - Values: Min: 0 / Max: 122070
 
 - downstream-rate
 - Specify the allocated downstream (access side) bandwidth. 
                        
- Default: 0 (unlimited, no bandwidth restrictions)
 - Values: Min: 0 / Max: 122070
 
 
Path
Data-flow is a subelement under the ike element. The full path from the topmost ACLI prompt is..
Note:
This is a multiple instance configuration element.