SNMP
The apSipSecInterfaceRegThresholdExceededTrap trap is generated when the total count of all registrations on the secondary interfaces cross sec-reg-threshold-exceed is exceeded.
Object Identifier Name: apSipInterfaceRegNotificationsGroup
Trap Name | Object Identifier Name: Number | Description |
---|---|---|
apSipSecInterfaceRegThresholdExceededTrap | .1.3.6.1.4.1.9148.3.15.2.1.2.0.1 | The trap will be generated if the total number of registrations on all secondary SIP interfaces exceed threshold. |
apSipSecInterfaceRegThresholdClearTrap | .1.3.6.1.4.1.9148.3.15.2.1.2.0.2 | The trap will be generated if the total number of registrations on all secondary SIP interfaces go below clear threshold. |
A hardware alarm is also generated for this event. The severity of the alarm is configured in the sec-reg-threshold-alarm-severity option.
Alarm Name | Alarm ID | Alarm Severity | Cause(s) | Example Log Message | Trap Generated (Trap Reference) |
---|---|---|---|---|---|
APP_ALARM_SEC_INTF_REG_EXCEED | 0X50018 | Minor by default. The severity is configurable. | The total number of registrations on all secondary SIP interfaces exceeds the configured threshold. | Number of Secondary Interface registrations <total> has exceeded the secondary interface registration threshold of <max>. | apSyslogMessageGenerated
(ap-slog.mib) apEnvMonStatusChangeNotification (ap-env-monitor.mib) apSysMgmtFanTrap (ap-smgmt.mib) |
The following objects, with the object identifier name apSipInterfaceRegObjectsGroup, monitor the number of registrations on secondary interfaces:
SNMP GET Query Name | Object Identifier Name: Number | Description |
---|---|---|
apSipSecInterfaceTotalRegistrations | .1.3.6.1.4.1.9148.3.15.1.1.1.1.0 | The total number of registrations on all secondary SIP interfaces. |
apSipSecInterfaceRegThreshold | .1.3.6.1.4.1.9148.3.15.1.1.1.2.0 | The max threshold for registrations on all secondary SIP interfaces beyond which trap and alarm will be raised |
apSipSecInterfaceClearThreshold | .1.3.6.1.4.1.9148.3.15.1.1.1.3.0 | The threshold for registrations on all secondary SIP interfaces below which if alarm was raised before, it will be cleared. |