Starting and Stopping Metered Service Matrix
The following matrix is representative of how a metered SP type's field activity type profile would look. The following points describe the rows, columns and cells in the matrix:
The customer events represent the three start and stop events that may take place at the service point.
Start service is the event that takes place when a service point is to be started and the system has no knowledge of a related stop event.
Stop service is the event that takes place when a service point is to be stopped and the system has no knowledge of a related start event.
Start/stop service is the event that takes place when a service point is to be stopped for one customer and started for another at the same time.
The SP conditions represent the state of service at a service point. The following conditions are represented:
A device (the meter) is either installed or not installed.
The installed device is either turned on or off.
The source of service (the line or pipe) is either connected to the service point or disconnected.
If the source is disconnected, define a field activity for each potential disconnect location.
Each cell in the matrix represents a field activity to be created by the system for the combination of customer event and service point condition.
SP Condition
Customer Event:
Start Service
Customer Event:
Stop Service
Customer Event:
Start/Stop Service
No Device / SP Disconnected at meter
Install meter and connect line
N/A - no field work is necessary because the meter should have been read when it was removed
N/A
No Device / SP Disconnected at pole
Install meter and connect line
N/A - no field work is necessary because the meter should have been read when it was removed
N/A
No Device / SP Connected
Install meter
N/A - no field work is necessary because the meter should have been read when it was removed
N/A
Device Installed / Device Off / SP Disconnected at meter
Connect line and turn on meter
N/A - no field work is necessary because the meter should have been read when the service was severed
N/A
Device Installed / Device Off / SP Disconnected at pole
Connect line and turn on meter
N/A - no field work is necessary because the meter should have been read when the service was severed
N/A
Device Installed / Device Off / SP Connected
Turn on meter
N/A - no field work is necessary because the meter should have been read when the meter was turned off
N/A
Device Installed / Device On / SP Connected
Read meter
Turn off meter
Read meter
Device Installed / Device On / SP Disconnected at meter
Connect line and read meter
N/A - no field work is necessary because the meter should have been read when the line was disconnected
N/A
Device Installed / Device On / SP Disconnected at pole
Connect line and read meter
N/A - no field work is necessary because the meter should have been read when the line was disconnected
N/A