Module Configurations
Module Configurations have application level properties used by all the SOA composites.
Module Name
Property Name
Default /
Shipped
Value
Description
C2M-NMS
C2M.Generic.MessageCategory
11114
This is the message category that the integration uses for C2M error messages.
C2M-NMS
C2M.GenericBusinessException.MessageNumber
11001
This is the message number the integration uses for Generic C2M error.
C2M-NMS
C2M.GenericDVMException.MessageNumber
11401
This is the message number the integration uses for DVM error.
C2M-NMS
NMS.MultipleInstance
false
This is the property to enable support for single or multiple NMS instance. Default value is false and false means integration support with single C2M integration and single NMS instance. Please refer the installation to configure multiple NMS instance.
C2M-NMS
SOA-INFRA.AuditLevel
ON
This property needs to be set to OFF if the Audit Level is set to off for the BPEL processes. If this is set to OFF the Error Handling does not use the composite and component instance IDs to log the error message.
C2M-NMS
ErrorHandling.GenericEmailID
 
This property is used to set the administrator email ID for the errorhandling process to send out an email in case of a critical failure where even the Errorhandling process fails.
C2M-NMS
DVM.OUC2M_OUNMS_ETR_SOURCE
.ThrowException
false
This flag indicates if an error is triggered when the DVM lookup value is not found for DVM OUC2M_OUNMS_ETR_SOURCE.
 
If set to true, the integration triggers a DVM exception error to the initiating application.
 
If set to false, the integration does not trigger any exception and instead passes the source application value as the default value to the target application.
C2M-NMS
NMS.CCBCallSourceID
CC
Source ID is required for NMS to identify the source system.
C2M-NMS
DVM.OUC2M_OUNMS_Job_History_Status
.ThrowException
false
This flag indicates if an error is triggered when the DVM lookup value is not found for DVM OUC2M_OUNMS_Job_History_Status.
 
If set to true, the integration triggers a DVM exception error to the initiating application.
 
If set to false, the integration does not trigger any exception and instead passes the source application value as the default value to the target application.
 
C2M-NMS
DVM.OUC2M_OUNMS_Alarm_State
.ThrowException
false
This flag indicates if an error is triggered when the DVM lookup value is not found for DVM OUC2M_OUNMS_Alarm_State.
 
If set to true, the integration triggers a DVM exception error to the initiating application.
 
If set to false, the integration does not trigger any exception and instead passes the source application value as the default value to the target application.
C2M-NMS
DVM.OUC2M_OUNMS_CALL_STATUS
.ThrowException
false
This flag indicates if an error is triggered when the DVM lookup value is not found for DVM OUC2M_OUNMS_CALL_STATUS.
If set to true, the integration triggers a DVM exception error to the initiating application.
 
If set to false, the integration does not trigger any exception and instead passes the source application value as the default value to the target application.
C2M-NMS
DVM.OUC2M_OUNMS_CallBackIndicator
.ThrowException
false
This flag indicates if an error is triggered when the DVM lookup value is not found for DVM OUC2M_OUNMS_CallBackIndicator.
If set to true, the integration triggers a DVM exception error to the initiating application.
 
If set to false, the integration does not trigger any exception and instead passes the source application value as the default value to the target application.
C2M-NMS
DVM.OUC2M_OUNMS_MeetType
.ThrowException
false
This flag indicates if an error is triggered when the DVM lookup value is not found for DVM.
If set to true, the integration triggers a DVM exception error to the initiating application.
 
If set to false, the integration does not trigger any exception and instead passes the source application value as the default value to the target application.
C2M-NMS
DVM.OUC2M_OUNMS_NewCallIndicator
.ThrowException
false
This flag indicates if an error is triggered when the DVM lookup value is not found for DVM.
 
If set to true, the integration triggers a DVM exception error to the initiating application.
 
If set to false, the integration does not trigger any exception and instead passes the source application value as the default value to the target application.
C2M-NMS
DVM.OUC2M_OUNMS_CallCancelIndicator
.ThrowException
false
This flag indicates if an error is triggered when the DVM lookup value is not found for DVM.
 
If set to true, the integration triggers a DVM exception error to the initiating application.
 
If set to false, the integration does not trigger any exception and instead passes the source application value as the default value to the target application.
C2M-NMS
DVM.OUC2M_OUNMS_AccountType
.ThrowException
false
This flag indicates if an error is triggered when the DVM lookup value is not found for DVM.
 
If set to true, the integration triggers a DVM exception error to the initiating application.
 
If set to false, the integration does not trigger any exception and instead passes the source application value as the default value to the target application.
C2M-NMS
DVM.OUC2M_OUNMS_MeterType
.ThrowException
false
This flag indicates if an error is triggered when the DVM lookup value is not found for DVM.
If set to true, the integration triggers a DVM exception error to the initiating application.
 
If set to false, the integration does not trigger any exception and instead passes the source application value as the default value to the target application.
C2M-NMS
DVM.OUC2M_OUNMS_Serv_C_Priority
.ThrowException
false
This flag indicates if an error is triggered when the DVM lookup value is not found for DVM.
 
If set to true, the integration triggers a DVM exception error to the initiating application.
 
If set to false, the integration does not trigger any exception and instead passes the source application value as the default value to the target application.
C2M-NMS
DVM.OUC2M_OUNMS_Serv_D_Priority
.ThrowException
false
This flag indicates if an error is triggered when the DVM lookup value is not found for DVM.
 
If set to true, the integration triggers a DVM exception error to the initiating application.
 
If set to false, the integration does not trigger any exception and instead passes the source application value as the default value to the target application.
C2M-NMS
DVM.OUC2M_OUNMS_Serv_K_Priority
.ThrowException
false
This flag indicates if an error is triggered when the DVM lookup value is not found for DVM.
 
If set to true, the integration triggers a DVM exception error to the initiating application.
 
If set to false, the integration does not trigger any exception and instead passes the source application value as the default value to the target application.
C2M-NMS
DVM.OUC2M_OUNMS_LifeSupportIndicator
.ThrowException
false
This flag indicates if an error is triggered when the DVM lookup value is not found for DVM.
 
If set to true, the integration triggers a DVM exception error to the initiating application.
 
If set to false, the integration does not trigger any exception and instead passes the source application value as the default value to the target application.
C2M-NMS
DVM.OUC2M_OUNMS_ErrorCode
.ThrowException
false
This flag is not used by the integration.
C2M-NMS
DVM.OUC2M_OUNMS_LifeSupportIndicator
_FALSE_VALUE
0
This is the NMS value for life support if it is false.
C2M-NMS
DVM.OUC2M_OUNMS_LifeSupportIndicator
_TRUE_VALUE
1
This is the NMS value for life support if it is true. This value is used to verify that the CCB life support value in the premise info or person info is true then the NMS value has to be set to true.
C2M-NMS
NMS.OUNMS_BaseURL
https://NMS_HOST.yourdomain.com:NMS_PORT_NO
The Default Base Endpoint URL for NMS REST Service instance applies for single or multi-instance.