Register DER Device
post
https://server:port/rest/apis/cross/digitalAssets/derDeviceManagement/register
This REST web service allows the registration of a Distributed Energy Resources (DER) device along with its IEEE 2030.5 nameplate ratings.
Request
There are no request parameters for this operation.
Supported Media Types
- application/xml
- application/json
Root Schema : schema
Type:
Show Source
object-
assetInfo: object
assetInfo
-
customerInfo: object
customerInfo
-
locationInfo: object
locationInfo
-
transactionId: string
Maximum Length:
120External Transaction ID
Nested Schema : assetInfo
Type:
Show Source
object-
attributes: object
attributes
-
headEndSystem: string
Maximum Length:
30Head end system, along with the NIC Id, is used to uniquely identify the device. For customer owned devices, these values are required for the registration process to create the controllable device record. -
registrationDate: string
(date)
Start date for the DER registration program
Nested Schema : customerInfo
Type:
Show Source
object-
businessPhone: string
Maximum Length:
24The business phone of the customer. Used to derive the existing customer and metered service record -
cisAccountId: string
Maximum Length:
30The CIS Account Id associated to the metered service point. Used to derive the existing customer and metered service record. Optional, if name is provided. -
cisPersonId: string
Maximum Length:
30The CIS Person Id associated to the metered service point. Used to derive the existing customer and metered service record. Optional, if name is provided. -
email: string
Maximum Length:
254The email address of the customer. Used to derive the existing customer and metered service record -
homePhone: string
Maximum Length:
24The home phone of the customer. Used to derive the existing customer and metered service record -
name: string
Maximum Length:
254The name of the customer. Used to derive the existing customer and metered service record
Nested Schema : locationInfo
Type:
Show Source
object-
address1: string
Maximum Length:
254The first line of the address. Used to derive the metered service point -
address2: string
Maximum Length:
254The second line of the address. Used to derive the metered service point -
address3: string
Maximum Length:
254The third line of the address. Used to derive the metered service point -
address4: string
Maximum Length:
254The fourth line of the address. Used to derive the metered service point -
cisPremiseId: string
Maximum Length:
60The CIS Premise Id associated to the metered service point. Used to derive the metered service point. Optional, if address information is provided. -
cisServicePointID: string
Maximum Length:
60The CIS Service Point Id associated to the metered service point. Used to derive the metered service point. Optional, if address information is provided. -
city: string
Maximum Length:
90The city of the address. Used to derive the metered service point -
country: string
Maximum Length:
3The country of the address. Used to derive the metered service point -
county: string
Maximum Length:
90The county of the address. Used to derive the metered service point -
division: string
Maximum Length:
30Division is used to define the jurisdiction in which the customer is located. -
postal: string
Maximum Length:
12The postal code of the address. Used to derive the metered service point -
state: string
Maximum Length:
6The state of the address. Used to derive the metered service point -
timeZone: string
Maximum Length:
10The time zone of the address
Nested Schema : DERCapability
Type:
Show Source
object-
modesSupported: string
Maximum Length:
254Indication of support for each control mode function -
rtgAbnormalCategory: string
Maximum Length:
254Indication of voltage and frequency ride-through category I, II, or III -
rtgMaxA: string
Maximum Length:
254Maximum continuous ac current capability of the DER, in amperes (rms) -
rtgMaxAh: string
Maximum Length:
254Usable energy storage capacity of DER in amp hours -
rtgMaxChargeRateVA: string
Maximum Length:
254Maximum apparent power charge rating in voltamperes; may differ from the apparent power maximum rating -
rtgMaxChargeRateW: string
Maximum Length:
254Maximum active power charge rating in watts -
rtgMaxDischargeRateVA: string
Maximum Length:
254Maximum apparent power discharge rating in voltamperes. May differ from the maximum apparent power rating. -
rtgMaxDischargeRateW: string
Maximum Length:
254Maximum rate of energy transfer delivered by the storage DER, in watts. Required for combined generation/storage DERs. -
rtgMaxV: string
Maximum Length:
254Maximum ac voltage rating in rms volts -
rtgMaxVA: string
Maximum Length:
254Maximum apparent power charge rating in volt amperes -
rtgMaxVar: string
Maximum Length:
254Maximum injected reactive power rating in vars -
rtgMaxVarNeg: string
Maximum Length:
254Maximum absorbed reactive power rating in vars -
rtgMaxW: string
Maximum Length:
254Active power rating in watts at unity power factor -
rtgMaxWh: string
Maximum Length:
254Maximum energy storage capacity of DER in watthours -
rtgMinPFOverExcited: string
Maximum Length:
254Minimum power factor displacement capability of the DER when injecting reactive power (over-excited) -
rtgMinPFUnderExcited: string
Maximum Length:
254Minimum Power Factor displacement capability of the DER when absorbing reactive power (under-excited) -
rtgMinV: string
Maximum Length:
254Minimum ac voltage rating in rms volts -
rtgNormalCategory: string
Maximum Length:
254Indication of reactive power and voltage/power control capability -
rtgOverExcitedPF: string
Maximum Length:
254Over-excited power factor -
rtgOverExcitedW: string
Maximum Length:
254Active power rating in watts at specified over-excited power factor -
rtgReactiveSusceptance: string
Maximum Length:
254Reactive susceptance that remains connected to the Area EPS in the cease to energize and trip state -
rtgUnderExcitedPF: string
Maximum Length:
254Active power rating in watts at specified under-excited power factor -
rtgUnderExcitedW: string
Maximum Length:
254Active power rating in watts at specified under-excited power factor -
rtgVNom: string
Maximum Length:
254Nominal ac voltage rating in rms volts -
type: string
Maximum Length:
254Type of DER
Nested Schema : DeviceInformation
Type:
Show Source
object-
aggregatorId: string
Maximum Length:
254Identifier of the entity through which a DER is reached, if not direct -
lFDI: string
Maximum Length:
254Long form of device identifier -
mfHwVer: string
Maximum Length:
254Hardware version -
mfID: string
Maximum Length:
254Manufacturer -
mfModel: string
Maximum Length:
254Model -
mfSerNum: string
Maximum Length:
254Serial number -
swVer: string
Maximum Length:
254Software version
Nested Schema : items
Type:
Show Source
object-
attribute: string
Maximum Length:
254Additional attribute name -
value: string
Maximum Length:
254Additional attribute value
Nested Schema : items
Type:
Show Source
object-
attribute: string
Maximum Length:
254Interconnection attribute name -
value: string
Maximum Length:
254Adhoc Characteristic Value
Root Schema : schema
Type:
Show Source
object-
assetInfo: object
assetInfo
-
customerInfo: object
customerInfo
-
locationInfo: object
locationInfo
-
transactionId: string
Maximum Length:
120External Transaction ID
Nested Schema : assetInfo
Type:
Show Source
object-
attributes: object
attributes
-
headEndSystem: string
Maximum Length:
30Head end system, along with the NIC Id, is used to uniquely identify the device. For customer owned devices, these values are required for the registration process to create the controllable device record. -
registrationDate: string
(date)
Start date for the DER registration program
Nested Schema : customerInfo
Type:
Show Source
object-
businessPhone: string
Maximum Length:
24The business phone of the customer. Used to derive the existing customer and metered service record -
cisAccountId: string
Maximum Length:
30The CIS Account Id associated to the metered service point. Used to derive the existing customer and metered service record. Optional, if name is provided. -
cisPersonId: string
Maximum Length:
30The CIS Person Id associated to the metered service point. Used to derive the existing customer and metered service record. Optional, if name is provided. -
email: string
Maximum Length:
254The email address of the customer. Used to derive the existing customer and metered service record -
homePhone: string
Maximum Length:
24The home phone of the customer. Used to derive the existing customer and metered service record -
name: string
Maximum Length:
254The name of the customer. Used to derive the existing customer and metered service record
Nested Schema : locationInfo
Type:
Show Source
object-
address1: string
Maximum Length:
254The first line of the address. Used to derive the metered service point -
address2: string
Maximum Length:
254The second line of the address. Used to derive the metered service point -
address3: string
Maximum Length:
254The third line of the address. Used to derive the metered service point -
address4: string
Maximum Length:
254The fourth line of the address. Used to derive the metered service point -
cisPremiseId: string
Maximum Length:
60The CIS Premise Id associated to the metered service point. Used to derive the metered service point. Optional, if address information is provided. -
cisServicePointID: string
Maximum Length:
60The CIS Service Point Id associated to the metered service point. Used to derive the metered service point. Optional, if address information is provided. -
city: string
Maximum Length:
90The city of the address. Used to derive the metered service point -
country: string
Maximum Length:
3The country of the address. Used to derive the metered service point -
county: string
Maximum Length:
90The county of the address. Used to derive the metered service point -
division: string
Maximum Length:
30Division is used to define the jurisdiction in which the customer is located. -
postal: string
Maximum Length:
12The postal code of the address. Used to derive the metered service point -
state: string
Maximum Length:
6The state of the address. Used to derive the metered service point -
timeZone: string
Maximum Length:
10The time zone of the address
Nested Schema : DERCapability
Type:
Show Source
object-
modesSupported: string
Maximum Length:
254Indication of support for each control mode function -
rtgAbnormalCategory: string
Maximum Length:
254Indication of voltage and frequency ride-through category I, II, or III -
rtgMaxA: string
Maximum Length:
254Maximum continuous ac current capability of the DER, in amperes (rms) -
rtgMaxAh: string
Maximum Length:
254Usable energy storage capacity of DER in amp hours -
rtgMaxChargeRateVA: string
Maximum Length:
254Maximum apparent power charge rating in voltamperes; may differ from the apparent power maximum rating -
rtgMaxChargeRateW: string
Maximum Length:
254Maximum active power charge rating in watts -
rtgMaxDischargeRateVA: string
Maximum Length:
254Maximum apparent power discharge rating in voltamperes. May differ from the maximum apparent power rating. -
rtgMaxDischargeRateW: string
Maximum Length:
254Maximum rate of energy transfer delivered by the storage DER, in watts. Required for combined generation/storage DERs. -
rtgMaxV: string
Maximum Length:
254Maximum ac voltage rating in rms volts -
rtgMaxVA: string
Maximum Length:
254Maximum apparent power charge rating in volt amperes -
rtgMaxVar: string
Maximum Length:
254Maximum injected reactive power rating in vars -
rtgMaxVarNeg: string
Maximum Length:
254Maximum absorbed reactive power rating in vars -
rtgMaxW: string
Maximum Length:
254Active power rating in watts at unity power factor -
rtgMaxWh: string
Maximum Length:
254Maximum energy storage capacity of DER in watthours -
rtgMinPFOverExcited: string
Maximum Length:
254Minimum power factor displacement capability of the DER when injecting reactive power (over-excited) -
rtgMinPFUnderExcited: string
Maximum Length:
254Minimum Power Factor displacement capability of the DER when absorbing reactive power (under-excited) -
rtgMinV: string
Maximum Length:
254Minimum ac voltage rating in rms volts -
rtgNormalCategory: string
Maximum Length:
254Indication of reactive power and voltage/power control capability -
rtgOverExcitedPF: string
Maximum Length:
254Over-excited power factor -
rtgOverExcitedW: string
Maximum Length:
254Active power rating in watts at specified over-excited power factor -
rtgReactiveSusceptance: string
Maximum Length:
254Reactive susceptance that remains connected to the Area EPS in the cease to energize and trip state -
rtgUnderExcitedPF: string
Maximum Length:
254Active power rating in watts at specified under-excited power factor -
rtgUnderExcitedW: string
Maximum Length:
254Active power rating in watts at specified under-excited power factor -
rtgVNom: string
Maximum Length:
254Nominal ac voltage rating in rms volts -
type: string
Maximum Length:
254Type of DER
Nested Schema : DeviceInformation
Type:
Show Source
object-
aggregatorId: string
Maximum Length:
254Identifier of the entity through which a DER is reached, if not direct -
lFDI: string
Maximum Length:
254Long form of device identifier -
mfHwVer: string
Maximum Length:
254Hardware version -
mfID: string
Maximum Length:
254Manufacturer -
mfModel: string
Maximum Length:
254Model -
mfSerNum: string
Maximum Length:
254Serial number -
swVer: string
Maximum Length:
254Software version
Nested Schema : items
Type:
Show Source
object-
attribute: string
Maximum Length:
254Additional attribute name -
value: string
Maximum Length:
254Additional attribute value
Nested Schema : items
Type:
Show Source
object-
attribute: string
Maximum Length:
254Interconnection attribute name -
value: string
Maximum Length:
254Adhoc Characteristic Value
Response
Supported Media Types
- application/xml
- application/json
200 Response
Success response
Root Schema : X1_RegDERDvc
Type:
Show Source
object-
enrollmentId: string
Maximum Length:
4Enrollment ID -
exception: object
exception
-
status: string
Maximum Length:
12Status -
transactionId: string
Maximum Length:
120External Transaction ID
Nested Schema : exception
Type:
Show Source
object-
expandedMessage: string
Maximum Length:
60Expanded message parameter -
messageCategory: string
Maximum Length:
5Message Category -
messageNumber: string
Maximum Length:
5Message Number
400 Response
Bad Request
Root Schema : problemDetailDocument
Type:
Show Source
object-
detail: string
Maximum Length:
60The long message description from the Oracle Utilities Application Framework in CDATA format. -
httpStatus: number
Minimum Value:
0Maximum Value:9999The HTTP Status code for the error. -
problemInstance: string
Maximum Length:
60Fully qualified URL consisting of the Base URI Timestamp of error in ISO format, the User used for the transaction, the Message Category within Oracle Utilities Application Framework, the Message Number within Oracle Utilities Application Framework, the Request URL and the HTTP method used for the transaction. -
problemType: string
Maximum Length:
60URL of the format "A/message/X/Y" where A is the base URI, X is the Message Category and Y is the Message Number within Oracle Utilities Application Framework. -
serverMessage: object
serverMessage
-
stackTrace: string
Maximum Length:
60The stack trace shows where the error occurs during the execution of a program. -
title: string
Maximum Length:
60Fully qualified error message from Oracle Utilities Application Framework in CDATA format.
Nested Schema : serverMessage
Type:
Show Source
object-
callSequence: string
Maximum Length:
60Delimited sequence of programs called. -
longDescription: string
Maximum Length:
60The long message description from the Oracle Utilities Application Framework in CDATA format. -
messageCategory: number
Minimum Value:
0Maximum Value:0Message Category within Oracle Utilities Application Framework. -
messageNbr: number
Minimum Value:
-99999Maximum Value:99999Message Number within Oracle Utilities Application Framework. -
messageText: string
Maximum Length:
60Fully qualified error message from Oracle Utilities Application Framework in CDATA format. -
programName: string
Maximum Length:
60Name of the program that encountered the error.
500 Response
Internal Server Error
Root Schema : problemDetailDocument
Type:
Show Source
object-
detail: string
Maximum Length:
60The long message description from the Oracle Utilities Application Framework in CDATA format. -
httpStatus: number
Minimum Value:
0Maximum Value:9999The HTTP Status code for the error. -
problemInstance: string
Maximum Length:
60Fully qualified URL consisting of the Base URI Timestamp of error in ISO format, the User used for the transaction, the Message Category within Oracle Utilities Application Framework, the Message Number within Oracle Utilities Application Framework, the Request URL and the HTTP method used for the transaction. -
problemType: string
Maximum Length:
60URL of the format "A/message/X/Y" where A is the base URI, X is the Message Category and Y is the Message Number within Oracle Utilities Application Framework. -
serverMessage: object
serverMessage
-
stackTrace: string
Maximum Length:
60The stack trace shows where the error occurs during the execution of a program. -
title: string
Maximum Length:
60Fully qualified error message from Oracle Utilities Application Framework in CDATA format.
Nested Schema : serverMessage
Type:
Show Source
object-
callSequence: string
Maximum Length:
60Delimited sequence of programs called. -
longDescription: string
Maximum Length:
60The long message description from the Oracle Utilities Application Framework in CDATA format. -
messageCategory: number
Minimum Value:
0Maximum Value:0Message Category within Oracle Utilities Application Framework. -
messageNbr: number
Minimum Value:
-99999Maximum Value:99999Message Number within Oracle Utilities Application Framework. -
messageText: string
Maximum Length:
60Fully qualified error message from Oracle Utilities Application Framework in CDATA format. -
programName: string
Maximum Length:
60Name of the program that encountered the error.