Register DER Device
post
https://server:port/rest/apis/cross/digitalAssets/derDeviceManagement/register
This REST web service allows the registration of a Distributed Energy Resources (DER) device along with its IEEE 2030.5 nameplate ratings.
Request
There are no request parameters for this operation.
Supported Media Types
- application/xml
- application/json
Root Schema : schema
Type:
Show Source
object
-
assetInfo: object
assetInfo
-
customerInfo: object
customerInfo
-
locationInfo: object
locationInfo
-
transactionId: string
Maximum Length:
120
External Transaction ID
Nested Schema : assetInfo
Type:
Show Source
object
-
attributes: object
attributes
-
headEndSystem: string
Maximum Length:
30
Head end system, along with the NIC Id, is used to uniquely identify the device. For customer owned devices, these values are required for the registration process to create the controllable device record. -
registrationDate: string
(date)
Start date for the DER registration program
Nested Schema : customerInfo
Type:
Show Source
object
-
businessPhone: string
Maximum Length:
24
The business phone of the customer. Used to derive the existing customer and metered service record -
cisAccountId: string
Maximum Length:
30
The CIS Account Id associated to the metered service point. Used to derive the existing customer and metered service record. Optional, if name is provided. -
cisPersonId: string
Maximum Length:
30
The CIS Person Id associated to the metered service point. Used to derive the existing customer and metered service record. Optional, if name is provided. -
email: string
Maximum Length:
254
The email address of the customer. Used to derive the existing customer and metered service record -
homePhone: string
Maximum Length:
24
The home phone of the customer. Used to derive the existing customer and metered service record -
name: string
Maximum Length:
254
The name of the customer. Used to derive the existing customer and metered service record
Nested Schema : locationInfo
Type:
Show Source
object
-
address1: string
Maximum Length:
254
The first line of the address. Used to derive the metered service point -
address2: string
Maximum Length:
254
The second line of the address. Used to derive the metered service point -
address3: string
Maximum Length:
254
The third line of the address. Used to derive the metered service point -
address4: string
Maximum Length:
254
The fourth line of the address. Used to derive the metered service point -
cisPremiseId: string
Maximum Length:
60
The CIS Premise Id associated to the metered service point. Used to derive the metered service point. Optional, if address information is provided. -
cisServicePointID: string
Maximum Length:
60
The CIS Service Point Id associated to the metered service point. Used to derive the metered service point. Optional, if address information is provided. -
city: string
Maximum Length:
90
The city of the address. Used to derive the metered service point -
country: string
Maximum Length:
3
The country of the address. Used to derive the metered service point -
county: string
Maximum Length:
90
The county of the address. Used to derive the metered service point -
division: string
Maximum Length:
30
Division is used to define the jurisdiction in which the customer is located. -
postal: string
Maximum Length:
12
The postal code of the address. Used to derive the metered service point -
state: string
Maximum Length:
6
The state of the address. Used to derive the metered service point -
timeZone: string
Maximum Length:
10
The time zone of the address
Nested Schema : DERCapability
Type:
Show Source
object
-
modesSupported: string
Maximum Length:
254
Indication of support for each control mode function -
rtgAbnormalCategory: string
Maximum Length:
254
Indication of voltage and frequency ride-through category I, II, or III -
rtgMaxA: string
Maximum Length:
254
Maximum continuous ac current capability of the DER, in amperes (rms) -
rtgMaxAh: string
Maximum Length:
254
Usable energy storage capacity of DER in amp hours -
rtgMaxChargeRateVA: string
Maximum Length:
254
Maximum apparent power charge rating in voltamperes; may differ from the apparent power maximum rating -
rtgMaxChargeRateW: string
Maximum Length:
254
Maximum active power charge rating in watts -
rtgMaxDischargeRateVA: string
Maximum Length:
254
Maximum apparent power discharge rating in voltamperes. May differ from the maximum apparent power rating. -
rtgMaxDischargeRateW: string
Maximum Length:
254
Maximum rate of energy transfer delivered by the storage DER, in watts. Required for combined generation/storage DERs. -
rtgMaxV: string
Maximum Length:
254
Maximum ac voltage rating in rms volts -
rtgMaxVA: string
Maximum Length:
254
Maximum apparent power charge rating in volt amperes -
rtgMaxVar: string
Maximum Length:
254
Maximum injected reactive power rating in vars -
rtgMaxVarNeg: string
Maximum Length:
254
Maximum absorbed reactive power rating in vars -
rtgMaxW: string
Maximum Length:
254
Active power rating in watts at unity power factor -
rtgMaxWh: string
Maximum Length:
254
Maximum energy storage capacity of DER in watthours -
rtgMinPFOverExcited: string
Maximum Length:
254
Minimum power factor displacement capability of the DER when injecting reactive power (over-excited) -
rtgMinPFUnderExcited: string
Maximum Length:
254
Minimum Power Factor displacement capability of the DER when absorbing reactive power (under-excited) -
rtgMinV: string
Maximum Length:
254
Minimum ac voltage rating in rms volts -
rtgNormalCategory: string
Maximum Length:
254
Indication of reactive power and voltage/power control capability -
rtgOverExcitedPF: string
Maximum Length:
254
Over-excited power factor -
rtgOverExcitedW: string
Maximum Length:
254
Active power rating in watts at specified over-excited power factor -
rtgReactiveSusceptance: string
Maximum Length:
254
Reactive susceptance that remains connected to the Area EPS in the cease to energize and trip state -
rtgUnderExcitedPF: string
Maximum Length:
254
Active power rating in watts at specified under-excited power factor -
rtgUnderExcitedW: string
Maximum Length:
254
Active power rating in watts at specified under-excited power factor -
rtgVNom: string
Maximum Length:
254
Nominal ac voltage rating in rms volts -
type: string
Maximum Length:
254
Type of DER
Nested Schema : DeviceInformation
Type:
Show Source
object
-
aggregatorId: string
Maximum Length:
254
Identifier of the entity through which a DER is reached, if not direct -
lFDI: string
Maximum Length:
254
Long form of device identifier -
mfHwVer: string
Maximum Length:
254
Hardware version -
mfID: string
Maximum Length:
254
Manufacturer -
mfModel: string
Maximum Length:
254
Model -
mfSerNum: string
Maximum Length:
254
Serial number -
swVer: string
Maximum Length:
254
Software version
Nested Schema : items
Type:
Show Source
object
-
attribute: string
Maximum Length:
254
Additional attribute name -
value: string
Maximum Length:
254
Additional attribute value
Nested Schema : items
Type:
Show Source
object
-
attribute: string
Maximum Length:
254
Interconnection attribute name -
value: string
Maximum Length:
254
Adhoc Characteristic Value
Root Schema : schema
Type:
Show Source
object
-
assetInfo: object
assetInfo
-
customerInfo: object
customerInfo
-
locationInfo: object
locationInfo
-
transactionId: string
Maximum Length:
120
External Transaction ID
Nested Schema : assetInfo
Type:
Show Source
object
-
attributes: object
attributes
-
headEndSystem: string
Maximum Length:
30
Head end system, along with the NIC Id, is used to uniquely identify the device. For customer owned devices, these values are required for the registration process to create the controllable device record. -
registrationDate: string
(date)
Start date for the DER registration program
Nested Schema : customerInfo
Type:
Show Source
object
-
businessPhone: string
Maximum Length:
24
The business phone of the customer. Used to derive the existing customer and metered service record -
cisAccountId: string
Maximum Length:
30
The CIS Account Id associated to the metered service point. Used to derive the existing customer and metered service record. Optional, if name is provided. -
cisPersonId: string
Maximum Length:
30
The CIS Person Id associated to the metered service point. Used to derive the existing customer and metered service record. Optional, if name is provided. -
email: string
Maximum Length:
254
The email address of the customer. Used to derive the existing customer and metered service record -
homePhone: string
Maximum Length:
24
The home phone of the customer. Used to derive the existing customer and metered service record -
name: string
Maximum Length:
254
The name of the customer. Used to derive the existing customer and metered service record
Nested Schema : locationInfo
Type:
Show Source
object
-
address1: string
Maximum Length:
254
The first line of the address. Used to derive the metered service point -
address2: string
Maximum Length:
254
The second line of the address. Used to derive the metered service point -
address3: string
Maximum Length:
254
The third line of the address. Used to derive the metered service point -
address4: string
Maximum Length:
254
The fourth line of the address. Used to derive the metered service point -
cisPremiseId: string
Maximum Length:
60
The CIS Premise Id associated to the metered service point. Used to derive the metered service point. Optional, if address information is provided. -
cisServicePointID: string
Maximum Length:
60
The CIS Service Point Id associated to the metered service point. Used to derive the metered service point. Optional, if address information is provided. -
city: string
Maximum Length:
90
The city of the address. Used to derive the metered service point -
country: string
Maximum Length:
3
The country of the address. Used to derive the metered service point -
county: string
Maximum Length:
90
The county of the address. Used to derive the metered service point -
division: string
Maximum Length:
30
Division is used to define the jurisdiction in which the customer is located. -
postal: string
Maximum Length:
12
The postal code of the address. Used to derive the metered service point -
state: string
Maximum Length:
6
The state of the address. Used to derive the metered service point -
timeZone: string
Maximum Length:
10
The time zone of the address
Nested Schema : DERCapability
Type:
Show Source
object
-
modesSupported: string
Maximum Length:
254
Indication of support for each control mode function -
rtgAbnormalCategory: string
Maximum Length:
254
Indication of voltage and frequency ride-through category I, II, or III -
rtgMaxA: string
Maximum Length:
254
Maximum continuous ac current capability of the DER, in amperes (rms) -
rtgMaxAh: string
Maximum Length:
254
Usable energy storage capacity of DER in amp hours -
rtgMaxChargeRateVA: string
Maximum Length:
254
Maximum apparent power charge rating in voltamperes; may differ from the apparent power maximum rating -
rtgMaxChargeRateW: string
Maximum Length:
254
Maximum active power charge rating in watts -
rtgMaxDischargeRateVA: string
Maximum Length:
254
Maximum apparent power discharge rating in voltamperes. May differ from the maximum apparent power rating. -
rtgMaxDischargeRateW: string
Maximum Length:
254
Maximum rate of energy transfer delivered by the storage DER, in watts. Required for combined generation/storage DERs. -
rtgMaxV: string
Maximum Length:
254
Maximum ac voltage rating in rms volts -
rtgMaxVA: string
Maximum Length:
254
Maximum apparent power charge rating in volt amperes -
rtgMaxVar: string
Maximum Length:
254
Maximum injected reactive power rating in vars -
rtgMaxVarNeg: string
Maximum Length:
254
Maximum absorbed reactive power rating in vars -
rtgMaxW: string
Maximum Length:
254
Active power rating in watts at unity power factor -
rtgMaxWh: string
Maximum Length:
254
Maximum energy storage capacity of DER in watthours -
rtgMinPFOverExcited: string
Maximum Length:
254
Minimum power factor displacement capability of the DER when injecting reactive power (over-excited) -
rtgMinPFUnderExcited: string
Maximum Length:
254
Minimum Power Factor displacement capability of the DER when absorbing reactive power (under-excited) -
rtgMinV: string
Maximum Length:
254
Minimum ac voltage rating in rms volts -
rtgNormalCategory: string
Maximum Length:
254
Indication of reactive power and voltage/power control capability -
rtgOverExcitedPF: string
Maximum Length:
254
Over-excited power factor -
rtgOverExcitedW: string
Maximum Length:
254
Active power rating in watts at specified over-excited power factor -
rtgReactiveSusceptance: string
Maximum Length:
254
Reactive susceptance that remains connected to the Area EPS in the cease to energize and trip state -
rtgUnderExcitedPF: string
Maximum Length:
254
Active power rating in watts at specified under-excited power factor -
rtgUnderExcitedW: string
Maximum Length:
254
Active power rating in watts at specified under-excited power factor -
rtgVNom: string
Maximum Length:
254
Nominal ac voltage rating in rms volts -
type: string
Maximum Length:
254
Type of DER
Nested Schema : DeviceInformation
Type:
Show Source
object
-
aggregatorId: string
Maximum Length:
254
Identifier of the entity through which a DER is reached, if not direct -
lFDI: string
Maximum Length:
254
Long form of device identifier -
mfHwVer: string
Maximum Length:
254
Hardware version -
mfID: string
Maximum Length:
254
Manufacturer -
mfModel: string
Maximum Length:
254
Model -
mfSerNum: string
Maximum Length:
254
Serial number -
swVer: string
Maximum Length:
254
Software version
Nested Schema : items
Type:
Show Source
object
-
attribute: string
Maximum Length:
254
Additional attribute name -
value: string
Maximum Length:
254
Additional attribute value
Nested Schema : items
Type:
Show Source
object
-
attribute: string
Maximum Length:
254
Interconnection attribute name -
value: string
Maximum Length:
254
Adhoc Characteristic Value
Response
Supported Media Types
- application/xml
- application/json
200 Response
Success response
Root Schema : X1_RegDERDvc
Type:
Show Source
object
-
enrollmentId: string
Maximum Length:
4
Enrollment ID -
exception: object
exception
-
status: string
Maximum Length:
12
Status -
transactionId: string
Maximum Length:
120
External Transaction ID
Nested Schema : exception
Type:
Show Source
object
-
expandedMessage: string
Maximum Length:
60
Expanded message parameter -
messageCategory: string
Maximum Length:
5
Message Category -
messageNumber: string
Maximum Length:
5
Message Number
400 Response
Bad Request
Root Schema : problemDetailDocument
Type:
Show Source
object
-
detail: string
Maximum Length:
60
The long message description from the Oracle Utilities Application Framework in CDATA format. -
httpStatus: number
Minimum Value:
0
Maximum Value:9999
The HTTP Status code for the error. -
problemInstance: string
Maximum Length:
60
Fully qualified URL consisting of the Base URI Timestamp of error in ISO format, the User used for the transaction, the Message Category within Oracle Utilities Application Framework, the Message Number within Oracle Utilities Application Framework, the Request URL and the HTTP method used for the transaction. -
problemType: string
Maximum Length:
60
URL of the format "A/message/X/Y" where A is the base URI, X is the Message Category and Y is the Message Number within Oracle Utilities Application Framework. -
serverMessage: object
serverMessage
-
stackTrace: string
Maximum Length:
60
The stack trace shows where the error occurs during the execution of a program. -
title: string
Maximum Length:
60
Fully qualified error message from Oracle Utilities Application Framework in CDATA format.
Nested Schema : serverMessage
Type:
Show Source
object
-
callSequence: string
Maximum Length:
60
Delimited sequence of programs called. -
longDescription: string
Maximum Length:
60
The long message description from the Oracle Utilities Application Framework in CDATA format. -
messageCategory: number
Minimum Value:
0
Maximum Value:0
Message Category within Oracle Utilities Application Framework. -
messageNbr: number
Minimum Value:
-99999
Maximum Value:99999
Message Number within Oracle Utilities Application Framework. -
messageText: string
Maximum Length:
60
Fully qualified error message from Oracle Utilities Application Framework in CDATA format. -
programName: string
Maximum Length:
60
Name of the program that encountered the error.
500 Response
Internal Server Error
Root Schema : problemDetailDocument
Type:
Show Source
object
-
detail: string
Maximum Length:
60
The long message description from the Oracle Utilities Application Framework in CDATA format. -
httpStatus: number
Minimum Value:
0
Maximum Value:9999
The HTTP Status code for the error. -
problemInstance: string
Maximum Length:
60
Fully qualified URL consisting of the Base URI Timestamp of error in ISO format, the User used for the transaction, the Message Category within Oracle Utilities Application Framework, the Message Number within Oracle Utilities Application Framework, the Request URL and the HTTP method used for the transaction. -
problemType: string
Maximum Length:
60
URL of the format "A/message/X/Y" where A is the base URI, X is the Message Category and Y is the Message Number within Oracle Utilities Application Framework. -
serverMessage: object
serverMessage
-
stackTrace: string
Maximum Length:
60
The stack trace shows where the error occurs during the execution of a program. -
title: string
Maximum Length:
60
Fully qualified error message from Oracle Utilities Application Framework in CDATA format.
Nested Schema : serverMessage
Type:
Show Source
object
-
callSequence: string
Maximum Length:
60
Delimited sequence of programs called. -
longDescription: string
Maximum Length:
60
The long message description from the Oracle Utilities Application Framework in CDATA format. -
messageCategory: number
Minimum Value:
0
Maximum Value:0
Message Category within Oracle Utilities Application Framework. -
messageNbr: number
Minimum Value:
-99999
Maximum Value:99999
Message Number within Oracle Utilities Application Framework. -
messageText: string
Maximum Length:
60
Fully qualified error message from Oracle Utilities Application Framework in CDATA format. -
programName: string
Maximum Length:
60
Name of the program that encountered the error.