Create Item
post
/rest/apis/meter/devices/items/
Request
There are no request parameters for this operation.
Supported Media Types
- application/xml
- application/json
Root Schema : schema
Type:
Show Source
object-
assetId: string
Maximum Length:
120The device identifier for the Asset ID.Example:LP3211 -
badgeNumber: string
Maximum Length:
120The device identifier for the Badge Number.Example:32505964 -
boStatus: string
Maximum Length:
12Status of the item deviceExample:ACTIVE -
characteristics: object
characteristics
-
configuration: string
Maximum Length:
120Configuration is the type of configurationExample:Badged Item KW -
creationDateTime: string
(date-time)
Create Date/TimeExample:
2020-10-12T22:35:28-07:00 -
externalId: string
Maximum Length:
60External identifier for the item device.Example:29256350 -
internalNumber: string
Maximum Length:
120The device identifier value for the internal number.Example:I-20140306001 -
itemId: string
Maximum Length:
12The Device or meter identifier in the source system.Example:881940890969 -
itemType: object
itemType
-
manufacturer: object
manufacturer
The Manufacturer of the device.
-
mdmExternalId: string
Maximum Length:
60MDM External ID for the item device.Example:32505964 -
model: string
Maximum Length:
30The specific model number of the device provided by the manufacturer.Example:ELECTRIC 4 -
retirementDateTime: string
(date-time)
Retirement Date/TimeExample:
2020-10-13T00:00:00-07:00 -
serialNumber: string
Maximum Length:
120The device identifier for the Serial Number.Example:SV100-60012 -
specification: string
Maximum Length:
120Specifications are used to define the manufacturer, model, and other information about the template device.Example:BIT_01 -
statusDateTime: string
(date-time)
Status Date/TimeExample:
2020-10-13T02:16:42-07:00 -
version: number
Minimum Value:
-99999Maximum Value:99999The Version number is used for internal concurrency checks.Example:5
Nested Schema : manufacturer
Type:
objectThe Manufacturer of the device.
Show Source
-
manufacturer: string
Maximum Length:
30The Manufacturer of the device.Example:GE
Nested Schema : items
Type:
Show Source
object-
characteristicType: object
characteristicType
-
characteristicValue: object
characteristicValue
-
effectiveDate: string
(date)
Effective Date
-
typeOfCharacteristicValue: string
Allowed Values:
[ "ADV ", "DFV ", "FKV ", "FLV " ]Type of Char Value: * `ADV ` - Adhoc Value, * `DFV ` - Predefined Value, * `FKV ` - Foreign Key Value, * `FLV ` - File Location Value -
version: number
Minimum Value:
-99999Maximum Value:99999The Version number is used for internal concurrency checks.Example:5
Nested Schema : characteristicType
Type:
Show Source
object-
characteristicType: string
Maximum Length:
8Characteristic Type
Nested Schema : characteristicValue
Type:
Show Source
object-
_link: string
(_link)
-
value: string
Maximum Length:
254Adhoc Characteristic Value -
value2: string
Maximum Length:
50Foreign Key Value 2 -
value3: string
Maximum Length:
50Foreign Key Value 3 -
value4: string
Maximum Length:
50Foreign Key Value 4 -
value5: string
Maximum Length:
50Foreign Key Value 5
Root Schema : schema
Type:
Show Source
object-
assetId: string
Maximum Length:
120The device identifier for the Asset ID.Example:LP3211 -
badgeNumber: string
Maximum Length:
120The device identifier for the Badge Number.Example:32505964 -
boStatus: string
Maximum Length:
12Status of the item deviceExample:ACTIVE -
characteristics: object
characteristics
-
configuration: string
Maximum Length:
120Configuration is the type of configurationExample:Badged Item KW -
creationDateTime: string
(date-time)
Create Date/TimeExample:
2020-10-12T22:35:28-07:00 -
externalId: string
Maximum Length:
60External identifier for the item device.Example:29256350 -
internalNumber: string
Maximum Length:
120The device identifier value for the internal number.Example:I-20140306001 -
itemId: string
Maximum Length:
12The Device or meter identifier in the source system.Example:881940890969 -
itemType: object
itemType
-
manufacturer: object
manufacturer
The Manufacturer of the device.
-
mdmExternalId: string
Maximum Length:
60MDM External ID for the item device.Example:32505964 -
model: string
Maximum Length:
30The specific model number of the device provided by the manufacturer.Example:ELECTRIC 4 -
retirementDateTime: string
(date-time)
Retirement Date/TimeExample:
2020-10-13T00:00:00-07:00 -
serialNumber: string
Maximum Length:
120The device identifier for the Serial Number.Example:SV100-60012 -
specification: string
Maximum Length:
120Specifications are used to define the manufacturer, model, and other information about the template device.Example:BIT_01 -
statusDateTime: string
(date-time)
Status Date/TimeExample:
2020-10-13T02:16:42-07:00 -
version: number
Minimum Value:
-99999Maximum Value:99999The Version number is used for internal concurrency checks.Example:5
Nested Schema : manufacturer
Type:
objectThe Manufacturer of the device.
Show Source
-
manufacturer: string
Maximum Length:
30The Manufacturer of the device.Example:GE
Nested Schema : items
Type:
Show Source
object-
characteristicType: object
characteristicType
-
characteristicValue: object
characteristicValue
-
effectiveDate: string
(date)
Effective Date
-
typeOfCharacteristicValue: string
Allowed Values:
[ "ADV ", "DFV ", "FKV ", "FLV " ]Type of Char Value: * `ADV ` - Adhoc Value, * `DFV ` - Predefined Value, * `FKV ` - Foreign Key Value, * `FLV ` - File Location Value -
version: number
Minimum Value:
-99999Maximum Value:99999The Version number is used for internal concurrency checks.Example:5
Nested Schema : characteristicType
Type:
Show Source
object-
characteristicType: string
Maximum Length:
8Characteristic Type
Nested Schema : characteristicValue
Type:
Show Source
object-
_link: string
(_link)
-
value: string
Maximum Length:
254Adhoc Characteristic Value -
value2: string
Maximum Length:
50Foreign Key Value 2 -
value3: string
Maximum Length:
50Foreign Key Value 3 -
value4: string
Maximum Length:
50Foreign Key Value 4 -
value5: string
Maximum Length:
50Foreign Key Value 5
Response
Supported Media Types
- application/xml
- application/json
200 Response
Success response
Root Schema : D1-Item
Type:
Show Source
object-
_self: string
_self
-
assetId: string
Maximum Length:
120The device identifier for the Asset ID.Example:LP3211 -
badgeNumber: string
Maximum Length:
120The device identifier for the Badge Number.Example:32505964 -
boStatus: string
Maximum Length:
12Status of the item deviceExample:ACTIVE -
characteristics: object
characteristics
-
configuration: string
Maximum Length:
120Configuration is the type of configurationExample:Badged Item KW -
creationDateTime: string
(date-time)
Create Date/TimeExample:
2020-10-12T22:35:28-07:00 -
externalId: string
Maximum Length:
60External identifier for the item device.Example:29256350 -
internalNumber: string
Maximum Length:
120The device identifier value for the internal number.Example:I-20140306001 -
itemId: string
Maximum Length:
12The Device or meter identifier in the source system.Example:881940890969 -
itemType: object
itemType
-
manufacturer: object
manufacturer
The Manufacturer of the device.
-
mdmExternalId: string
Maximum Length:
60MDM External ID for the item device.Example:32505964 -
model: string
Maximum Length:
30The specific model number of the device provided by the manufacturer.Example:ELECTRIC 4 -
retirementDateTime: string
(date-time)
Retirement Date/TimeExample:
2020-10-13T00:00:00-07:00 -
serialNumber: string
Maximum Length:
120The device identifier for the Serial Number.Example:SV100-60012 -
specification: string
Maximum Length:
120Specifications are used to define the manufacturer, model, and other information about the template device.Example:BIT_01 -
statusDateTime: string
(date-time)
Status Date/TimeExample:
2020-10-13T02:16:42-07:00 -
version: number
Minimum Value:
-99999Maximum Value:99999The Version number is used for internal concurrency checks.Example:5
Nested Schema : itemType
Type:
Show Source
object-
_link: string
_link
-
deviceType: string
Maximum Length:
30Device Type
Nested Schema : manufacturer
Type:
objectThe Manufacturer of the device.
Show Source
-
_link: string
_link
-
manufacturer: string
Maximum Length:
30The Manufacturer of the device.Example:GE
Nested Schema : items
Type:
Show Source
object-
characteristicType: object
characteristicType
-
characteristicValue: object
characteristicValue
-
effectiveDate: string
(date)
Effective Date
-
typeOfCharacteristicValue: string
Allowed Values:
[ "ADV ", "DFV ", "FKV ", "FLV " ]Type of Char Value: * `ADV ` - Adhoc Value, * `DFV ` - Predefined Value, * `FKV ` - Foreign Key Value, * `FLV ` - File Location Value -
version: number
Minimum Value:
-99999Maximum Value:99999The Version number is used for internal concurrency checks.Example:5
Nested Schema : characteristicType
Type:
Show Source
object-
_link: string
_link
-
characteristicType: string
Maximum Length:
8Characteristic Type
Nested Schema : characteristicValue
Type:
Show Source
object-
_link: string
(_link)
-
value: string
Maximum Length:
254Adhoc Characteristic Value -
value2: string
Maximum Length:
50Foreign Key Value 2 -
value3: string
Maximum Length:
50Foreign Key Value 3 -
value4: string
Maximum Length:
50Foreign Key Value 4 -
value5: string
Maximum Length:
50Foreign Key Value 5
400 Response
Bad Request
Root Schema : problemDetailDocument
Type:
Show Source
object-
detail: string
Maximum Length:
60The long message description from the Oracle Utilities Application Framework in CDATA format. -
httpStatus: number
Minimum Value:
0Maximum Value:9999The HTTP Status code for the error. -
problemInstance: string
Maximum Length:
60Fully qualified URL consisting of the Base URI Timestamp of error in ISO format, the User used for the transaction, the Message Category within Oracle Utilities Application Framework, the Message Number within Oracle Utilities Application Framework, the Request URL and the HTTP method used for the transaction. -
problemType: string
Maximum Length:
60URL of the format "A/message/X/Y" where A is the base URI, X is the Message Category and Y is the Message Number within Oracle Utilities Application Framework. -
serverMessage: object
serverMessage
-
stackTrace: string
Maximum Length:
60The stack trace shows where the error occurs during the execution of a program. -
title: string
Maximum Length:
60Fully qualified error message from Oracle Utilities Application Framework in CDATA format.
Nested Schema : serverMessage
Type:
Show Source
object-
callSequence: string
Maximum Length:
60Delimited sequence of programs called. -
longDescription: string
Maximum Length:
60The long message description from the Oracle Utilities Application Framework in CDATA format. -
messageCategory: number
Minimum Value:
0Maximum Value:0Message Category within Oracle Utilities Application Framework. -
messageNbr: number
Minimum Value:
-99999Maximum Value:99999Message Number within Oracle Utilities Application Framework. -
messageText: string
Maximum Length:
60Fully qualified error message from Oracle Utilities Application Framework in CDATA format. -
programName: string
Maximum Length:
60Name of the program that encountered the error.
500 Response
Internal Server Error
Root Schema : problemDetailDocument
Type:
Show Source
object-
detail: string
Maximum Length:
60The long message description from the Oracle Utilities Application Framework in CDATA format. -
httpStatus: number
Minimum Value:
0Maximum Value:9999The HTTP Status code for the error. -
problemInstance: string
Maximum Length:
60Fully qualified URL consisting of the Base URI Timestamp of error in ISO format, the User used for the transaction, the Message Category within Oracle Utilities Application Framework, the Message Number within Oracle Utilities Application Framework, the Request URL and the HTTP method used for the transaction. -
problemType: string
Maximum Length:
60URL of the format "A/message/X/Y" where A is the base URI, X is the Message Category and Y is the Message Number within Oracle Utilities Application Framework. -
serverMessage: object
serverMessage
-
stackTrace: string
Maximum Length:
60The stack trace shows where the error occurs during the execution of a program. -
title: string
Maximum Length:
60Fully qualified error message from Oracle Utilities Application Framework in CDATA format.
Nested Schema : serverMessage
Type:
Show Source
object-
callSequence: string
Maximum Length:
60Delimited sequence of programs called. -
longDescription: string
Maximum Length:
60The long message description from the Oracle Utilities Application Framework in CDATA format. -
messageCategory: number
Minimum Value:
0Maximum Value:0Message Category within Oracle Utilities Application Framework. -
messageNbr: number
Minimum Value:
-99999Maximum Value:99999Message Number within Oracle Utilities Application Framework. -
messageText: string
Maximum Length:
60Fully qualified error message from Oracle Utilities Application Framework in CDATA format. -
programName: string
Maximum Length:
60Name of the program that encountered the error.