Create Measuring Component
post
https://server:port/ouaf/rest/apis/meter/devices/measuringComponents/
Request
There are no request parameters for this operation.
Supported Media Types
- application/xml
- application/json
Root Schema : schema
Type:
Show Source
object-
businessObject: string
Maximum Length:
30Business ObjectExample:D1-IntervalChannel -
consumptionReferenceMC: object
consumptionReferenceMC
-
creationDateTime: string
(date-time)
Create Date/TimeExample:
2011-04-20T09:03:54-07:00 -
deviceConfigurationId: string
Maximum Length:
12Device Configuration ID is a system assigned random number that stays with a device configuration record.Example:959682277977 -
fallBackVeeGroups: object
fallBackVeeGroups
-
fullScale: number
Minimum Value:
-1.0E11Maximum Value:1.0E11Full ScaleExample:0E-7 -
howToUse: string
Allowed Values:
[ "+ ", "- ", "C ", "P " ]How to Use indicates how the channel is used (additive, subtractive, peak, or check) when calculating usage. * `+ ` - Additive, * `- ` - Subtractive, * `C ` - Check, * `P ` - Peak -
measuringComponentId: string
Maximum Length:
12Measuring Component ID is a system assigned random number that stays with measuring component record.Example:061924013788 -
measuringComponentMultiplier: number
Minimum Value:
-999999.999999Maximum Value:999999.999999The meter multiplier for the channel.Example:1 -
measuringComponentType: object
measuringComponentType
Type of Measuring Component
-
numberOfDigitsLeft: number
Minimum Value:
-99999Maximum Value:99999Number of digits left is the number of digits to the left of the decimal point that the reading can contain.Example:3 -
numberOfDigitsRight: number
Minimum Value:
-99999Maximum Value:99999Number of digits right is the number of digits to the right of the decimal point that the reading can contain.Example:2 -
readSequence: number
Minimum Value:
-99999Maximum Value:99999Read SequenceExample:0 -
veeGroups: object
veeGroups
-
version: number
Minimum Value:
-99999Maximum Value:99999The Version number is used for internal concurrency checks.Example:1
Nested Schema : consumptionReferenceMC
Type:
Show Source
object-
consumptionReferenceMCId: string
Maximum Length:
12Related scalar measuring component. Used when adjusting interval measurement data to an existing scalar measurement.
Nested Schema : measuringComponentType
Type:
objectType of Measuring Component
Show Source
-
measuringComponentType: string
Maximum Length:
30Type of Measuring ComponentExample:MKA SMART KWH
Nested Schema : initialLoad
Type:
Show Source
object-
initialLoad: string
Maximum Length:
30VEE Group
Nested Schema : manualOverride
Type:
Show Source
object-
manualOverride: string
Maximum Length:
30VEE Group
Nested Schema : streamingInitialLoad
Type:
Show Source
object-
streamingInitialLoad: string
Maximum Length:
30VEE Group
Nested Schema : initialLoad
Type:
Show Source
object-
initialLoad: string
Maximum Length:
30VEE Group
Nested Schema : manualOverride
Type:
Show Source
object-
manualOverride: string
Maximum Length:
30VEE Group
Nested Schema : streamingInitialLoad
Type:
Show Source
object-
streamingInitialLoad: string
Maximum Length:
30VEE Group
Root Schema : schema
Type:
Show Source
object-
businessObject: string
Maximum Length:
30Business ObjectExample:D1-IntervalChannel -
consumptionReferenceMC: object
consumptionReferenceMC
-
creationDateTime: string
(date-time)
Create Date/TimeExample:
2011-04-20T09:03:54-07:00 -
deviceConfigurationId: string
Maximum Length:
12Device Configuration ID is a system assigned random number that stays with a device configuration record.Example:959682277977 -
fallBackVeeGroups: object
fallBackVeeGroups
-
fullScale: number
Minimum Value:
-1.0E11Maximum Value:1.0E11Full ScaleExample:0E-7 -
howToUse: string
Allowed Values:
[ "+ ", "- ", "C ", "P " ]How to Use indicates how the channel is used (additive, subtractive, peak, or check) when calculating usage. * `+ ` - Additive, * `- ` - Subtractive, * `C ` - Check, * `P ` - Peak -
measuringComponentId: string
Maximum Length:
12Measuring Component ID is a system assigned random number that stays with measuring component record.Example:061924013788 -
measuringComponentMultiplier: number
Minimum Value:
-999999.999999Maximum Value:999999.999999The meter multiplier for the channel.Example:1 -
measuringComponentType: object
measuringComponentType
Type of Measuring Component
-
numberOfDigitsLeft: number
Minimum Value:
-99999Maximum Value:99999Number of digits left is the number of digits to the left of the decimal point that the reading can contain.Example:3 -
numberOfDigitsRight: number
Minimum Value:
-99999Maximum Value:99999Number of digits right is the number of digits to the right of the decimal point that the reading can contain.Example:2 -
readSequence: number
Minimum Value:
-99999Maximum Value:99999Read SequenceExample:0 -
veeGroups: object
veeGroups
-
version: number
Minimum Value:
-99999Maximum Value:99999The Version number is used for internal concurrency checks.Example:1
Nested Schema : consumptionReferenceMC
Type:
Show Source
object-
consumptionReferenceMCId: string
Maximum Length:
12Related scalar measuring component. Used when adjusting interval measurement data to an existing scalar measurement.
Nested Schema : measuringComponentType
Type:
objectType of Measuring Component
Show Source
-
measuringComponentType: string
Maximum Length:
30Type of Measuring ComponentExample:MKA SMART KWH
Nested Schema : initialLoad
Type:
Show Source
object-
initialLoad: string
Maximum Length:
30VEE Group
Nested Schema : manualOverride
Type:
Show Source
object-
manualOverride: string
Maximum Length:
30VEE Group
Nested Schema : streamingInitialLoad
Type:
Show Source
object-
streamingInitialLoad: string
Maximum Length:
30VEE Group
Nested Schema : initialLoad
Type:
Show Source
object-
initialLoad: string
Maximum Length:
30VEE Group
Nested Schema : manualOverride
Type:
Show Source
object-
manualOverride: string
Maximum Length:
30VEE Group
Nested Schema : streamingInitialLoad
Type:
Show Source
object-
streamingInitialLoad: string
Maximum Length:
30VEE Group
Response
Supported Media Types
- application/xml
- application/json
200 Response
Success response
Root Schema : D1MeasuComp
Type:
Show Source
object-
_self: string
_self
-
adjustLatestMeasurementDateTime: string
(date-time)
Adjust Latest Measurement Date/Time
-
businessObject: string
Maximum Length:
30Business ObjectExample:D1-IntervalChannel -
consumptionReferenceMC: object
consumptionReferenceMC
-
creationDateTime: string
(date-time)
Create Date/TimeExample:
2011-04-20T09:03:54-07:00 -
deviceConfiguration: object
deviceConfiguration
-
fallBackVeeGroups: object
fallBackVeeGroups
-
fullScale: number
Minimum Value:
-1.0E11Maximum Value:1.0E11Full ScaleExample:0E-7 -
howToUse: string
Allowed Values:
[ "+ ", "- ", "C ", "P " ]How to Use indicates how the channel is used (additive, subtractive, peak, or check) when calculating usage. * `+ ` - Additive, * `- ` - Subtractive, * `C ` - Check, * `P ` - Peak -
latestMeasurementDateTime: string
(date-time)
Latest Measurement Date/Time
-
measuringComponentId: string
Maximum Length:
12Measuring Component ID is a system assigned random number that stays with measuring component record.Example:061924013788 -
measuringComponentMultiplier: number
Minimum Value:
-999999.999999Maximum Value:999999.999999The meter multiplier for the channel.Example:1 -
measuringComponentType: object
measuringComponentType
Type of Measuring Component
-
mostRecentMeasurementDateTime: string
(date-time)
This date/time corresponds to the final measurement with the latest measurement date/time that has been processed for this measuring component regardless of the final condition (i.e. quality).
-
mostRecentMeasurementReadingCondition: string
Maximum Length:
6Most Recent Measurement Reading Condition -
mostRecentMeasurementReadingValue: number
Minimum Value:
0Maximum Value:9.999999999999998E9Most Recent Measurement Reading ValueExample:0 -
mostRecentNonEstimatedMeasurementDateTime: string
(date-time)
This date/time corresponds to the final measurement with the latest measurement date/time that has a final condition that is non-estimated.
-
numberOfDigitsLeft: number
Minimum Value:
-99999Maximum Value:99999Number of digits left is the number of digits to the left of the decimal point that the reading can contain.Example:3 -
numberOfDigitsRight: number
Minimum Value:
-99999Maximum Value:99999Number of digits right is the number of digits to the right of the decimal point that the reading can contain.Example:2 -
readSequence: number
Minimum Value:
-99999Maximum Value:99999Read SequenceExample:0 -
veeGroups: object
veeGroups
-
version: number
Minimum Value:
-99999Maximum Value:99999The Version number is used for internal concurrency checks.Example:1
Nested Schema : consumptionReferenceMC
Type:
Show Source
object-
_link: string
_link
-
consumptionReferenceMCId: string
Maximum Length:
12Related scalar measuring component. Used when adjusting interval measurement data to an existing scalar measurement.
Nested Schema : deviceConfiguration
Type:
Show Source
object-
_link: string
_link
-
deviceConfigurationId: string
Maximum Length:
12Device Configuration ID is a system assigned random number that stays with a device configuration record.Example:959682277977
Nested Schema : measuringComponentType
Type:
objectType of Measuring Component
Show Source
-
_link: string
_link
-
measuringComponentType: string
Maximum Length:
30Type of Measuring ComponentExample:MKA SMART KWH
Nested Schema : estimation
Type:
Show Source
object-
_link: string
_link
-
estimation: string
Maximum Length:
30VEE Group
Nested Schema : initialLoad
Type:
Show Source
object-
_link: string
_link
-
initialLoad: string
Maximum Length:
30VEE Group
Nested Schema : manualOverride
Type:
Show Source
object-
_link: string
_link
-
manualOverride: string
Maximum Length:
30VEE Group
Nested Schema : projection
Type:
Show Source
object-
_link: string
_link
-
projection: string
Maximum Length:
30VEE Group
Nested Schema : streamingInitialLoad
Type:
Show Source
object-
_link: string
_link
-
streamingInitialLoad: string
Maximum Length:
30VEE Group
Nested Schema : estimation
Type:
Show Source
object-
_link: string
_link
-
estimation: string
Maximum Length:
30VEE Group
Nested Schema : initialLoad
Type:
Show Source
object-
_link: string
_link
-
initialLoad: string
Maximum Length:
30VEE Group
Nested Schema : manualOverride
Type:
Show Source
object-
_link: string
_link
-
manualOverride: string
Maximum Length:
30VEE Group
Nested Schema : projection
Type:
Show Source
object-
_link: string
_link
-
projection: string
Maximum Length:
30VEE Group
Nested Schema : streamingInitialLoad
Type:
Show Source
object-
_link: string
_link
-
streamingInitialLoad: string
Maximum Length:
30VEE Group
400 Response
Bad Request
Root Schema : problemDetailDocument
Type:
Show Source
object-
detail: string
Maximum Length:
60The long message description from the Oracle Utilities Application Framework in CDATA format. -
httpStatus: number
Minimum Value:
0Maximum Value:9999The HTTP Status code for the error. -
problemInstance: string
Maximum Length:
60Fully qualified URL consisting of the Base URI Timestamp of error in ISO format, the User used for the transaction, the Message Category within Oracle Utilities Application Framework, the Message Number within Oracle Utilities Application Framework, the Request URL and the HTTP method used for the transaction. -
problemType: string
Maximum Length:
60URL of the format "A/message/X/Y" where A is the base URI, X is the Message Category and Y is the Message Number within Oracle Utilities Application Framework. -
serverMessage: object
serverMessage
-
stackTrace: string
Maximum Length:
60The stack trace shows where the error occurs during the execution of a program. -
title: string
Maximum Length:
60Fully qualified error message from Oracle Utilities Application Framework in CDATA format.
Nested Schema : serverMessage
Type:
Show Source
object-
callSequence: string
Maximum Length:
60Delimited sequence of programs called. -
longDescription: string
Maximum Length:
60The long message description from the Oracle Utilities Application Framework in CDATA format. -
messageCategory: number
Minimum Value:
0Maximum Value:0Message Category within Oracle Utilities Application Framework. -
messageNbr: number
Minimum Value:
-99999Maximum Value:99999Message Number within Oracle Utilities Application Framework. -
messageText: string
Maximum Length:
60Fully qualified error message from Oracle Utilities Application Framework in CDATA format. -
programName: string
Maximum Length:
60Name of the program that encountered the error.
500 Response
Internal Server Error
Root Schema : problemDetailDocument
Type:
Show Source
object-
detail: string
Maximum Length:
60The long message description from the Oracle Utilities Application Framework in CDATA format. -
httpStatus: number
Minimum Value:
0Maximum Value:9999The HTTP Status code for the error. -
problemInstance: string
Maximum Length:
60Fully qualified URL consisting of the Base URI Timestamp of error in ISO format, the User used for the transaction, the Message Category within Oracle Utilities Application Framework, the Message Number within Oracle Utilities Application Framework, the Request URL and the HTTP method used for the transaction. -
problemType: string
Maximum Length:
60URL of the format "A/message/X/Y" where A is the base URI, X is the Message Category and Y is the Message Number within Oracle Utilities Application Framework. -
serverMessage: object
serverMessage
-
stackTrace: string
Maximum Length:
60The stack trace shows where the error occurs during the execution of a program. -
title: string
Maximum Length:
60Fully qualified error message from Oracle Utilities Application Framework in CDATA format.
Nested Schema : serverMessage
Type:
Show Source
object-
callSequence: string
Maximum Length:
60Delimited sequence of programs called. -
longDescription: string
Maximum Length:
60The long message description from the Oracle Utilities Application Framework in CDATA format. -
messageCategory: number
Minimum Value:
0Maximum Value:0Message Category within Oracle Utilities Application Framework. -
messageNbr: number
Minimum Value:
-99999Maximum Value:99999Message Number within Oracle Utilities Application Framework. -
messageText: string
Maximum Length:
60Fully qualified error message from Oracle Utilities Application Framework in CDATA format. -
programName: string
Maximum Length:
60Name of the program that encountered the error.