Configuring Silver Spring Networks Extendable Lookups
Note:
This section applies to both middleware and native implementations of the Smart Grid Gateway Adapter for Silver Spring Networks.
This section outlines some of the extendable lookups that must be configured for use with the Silver Spring Networks adapter. Refer to the Oracle Utilities Application Framework documentation for more information about working with extendable lookups.
Device Event Mapping
The Device Event Mapping extendable lookup is used to determine which type of device event business object to instantiate when receiving device events from the head-end system. Each value defined for the Device Event Mapping extendable lookup should include the following:
Head-End System Event Name: The event name used by the head-end system.
Description: A description of the device event.
Status: The status of the lookup value (can be Active or Inactive).
Standard Event Name: The standard event name for device events of this type, from the “Standard Event Name” extendable lookup.
UOM Code to Standard UOM Mapping
Usage received from a utility’s head-end system may use utility-specific unit of measures (UOMs). These custom UOMs must be mapped to standard UOM codes. The UOM Code to Standard UOM Mapping extendable lookup is used for this purpose. Each value defined for the UOM Code to Standard UOM Mapping extendable lookup should include the following:
Head-End Unit of Measure: The unit of measure code used by the head-end system.
Description: A description of the unit of measure code.
Status: The status of the lookup value (can be Active or Inactive).
Unit of Measure: The unit of measure defined in the system.
Interval Status Code to Condition Mapping
Interval usage received from the Silver Spring Networks UtilityIQ can include Silver Spring Networks interval status codes that indicate the status or condition of the interval value. These interval status codes must be mapped to standard condition codes in the system. The Silver Spring Networks Interval Status Code to Condition Mapping extendable lookup is used to determine how to map Silver Spring Networks interval status codes to standard status codes when receiving usage from the Silver Spring Networks UtilityIQ.
Each value defined for the Silver Spring Networks Interval Status Code to Condition Mapping extendable lookup should include the following:
Interval Status: The Silver Spring Networks interval status code
Description: A description of the interval status code.
Status: The status of the lookup value (can be Active or Inactive)
Condition: The condition code to which the interval status code is to be mapped, from the Measurement Condition extendable lookup.
Other Extendable Lookups
Business Object Name
Description
 D7-ActivationStatusLookup
 SSN - Activation Status
 D7-ChannelStatusLookup
 SSN - Channel Status
 D7-DataTimeZoneLookup
 SSN - Data Time Zone
 D7-DeviceStatusLookup
 SSN - Device Status
 D7-ExecutionStatusLookup
 SSN - Execution Status
 D7-HeadendSQILookup
 SSN - Head-End SQI to Standard SQI
 D7-HeadendTOULookup
 SSN - Head-End TOU to Standard TOU
 D7-IntervalStatusLookup
 SSN - Interval Status
 D7-MeterConnectionStatusLookup
 SSN - Meter Connection Status
 D7-MeterReadTypeLookup
 SSN - Meter Read Type
 D7-OldAdminStateNameLookup
 SSN - Old Admin State Name
 D7-PriorityLookup
 SSN - Priority Status
 D7-ProvisioningActionLookup
 SSN - Provisioning Action
 D7-ProvisioningCommandStatus
 SSN - Provisioning Command Status
 D7-ProvisioningDataType
 SSN - Provisioning Data Type
 D7-ReadModeLookup
 SSN - Read Mode
 D7-RegisterReadSourceLookup
 SSN - Register Read Source
 D7-RegisterStatusLookup
 SSN - Register Status
 D7-SSNVersionLookup
 SSN - Version
 D7-StatusFlagNameLookup
 SSN - Status Flag Name