Dynamic Comparison Validation
This validation rule compares measurements to historical statistics for the related Service Point. The system will maintain statistics such as the following: sum, min, max, average, median, zero value count, outage count, and standard deviation. Setting up these Measuring Component Statistics is a prerequisite to using the rule.
Users can define formulas (no programming required) for the comparison of current measurements to these statistics. This is powerful rule will allow utilities to look for unusual usage patterns. For example:
Lowest/highest usage ever
Current usage is more than three standard deviations from the mean
Detect unexpected zero usage
Detect negative usage while ruling out known cases
Abnormal usage
Voltage threshold monitoring
Note: 
Additional detail on the logic of this rule can be found in the Detailed Description of the D2-DYNCOMCHK Algorithm Type.
For help with the meaning of specific configuration fields, refer to the embedded help on the screen when adding or editing the rule.
Business Object
D2-DynCompValidation
Example Scenarios
Below are some example scenarios that can be achieved based on configuration of this rule.
Example 1: Detect new "high water mark"
Example Scenarios
Example 2: High Usage
Example Scenarios
Example 3: Detect unexpected zero usage (method 1)
Example Scenarios
Example 4: Detect unexpected zero usage (method 2)
Example Scenarios
Example 5: Detect negative usage while ruling out known cases
Example Scenarios
Example 6: Abnormal usage
Example Scenarios
Example 7: Voltage threshold monitoring
Example Scenarios