Inactive Measurement Check
This validation rule flags any Initial Measurement Data received on a device that is either disconnected, uninstalled, and/or not connected to a usage subscription.
When the 'Check Measurements on Disconnected Device' flag is set to "Yes", the logic will compare the IMD measurements total to the threshold configured. If the total measurements are above the threshold, then logic compares the IMD dates to two things: 1) On/Off Dates related to the Install Event and 2) the Installation and Removal Dates of the Install Event. If the On or Off falls within the dates for an interval IMD, then the logic will only sum intervals that fall during the disconnected periods.
When the 'Check for Uninstalled Device' flag is set to "Yes", the logic will check for a valid Install Event based on the IMD dates.
When the 'Check for Missing Usage Subscription' flag is set to "Yes", the logic will check for an active Usage Subscription based on the IMD dates.
Note: 
Additional detail on the logic of this rule can be found in the Detailed Description of the D2-INACTVCHK Algorithm Type.
For help with the meaning of specific configuration fields, refer to the embedded help on the screen when adding or editing the rule.
Business Object
D2-InactiveMeasurementCheck
Example Scenarios
Below are some example scenarios that can be achieved based on configuration of this rule.
Example 1: Non-zero data during disconnected period
Example Scenarios
Example 2: Non-zero data after removal date with no new install
Example Scenarios
Example 3: Data received when device has no Install Event records
Example Scenarios
Example 4: Data received when not connected to a Usage Subscription record
Example Scenarios