Message Senders
Message senders define the details of how messages are sent to an external system, such as messages containing device command requests.
The following message senders must be configured in your system. If these are not present in your configuration, add them. Refer to the Oracle Utilities Application Framework documentation for more information about creating message senders.
Message Sender
Description
D3-Comms
Commission Device
D3-Connect
Connect Device
D3-Decomm
Decommission Device
D3-InitMTR
Initiate Meter Read by Meter Number Outbound Message
D3-RTSender
Real Time Sender
D3-RTSnd
Real-time Sender (Landis+Gyr)
D3_​CIMODR
L+G CIM On Demand Read
D3_​CIMPING
L+G CIM Ping
D3_​SCHDEMRES
L+G Schedule Demand Reset
Note: The following apply to all of the above message senders:
Main Tab:
Invocation Type: Real-time
Message Class: RTHTTPSNDR (Sender routes message via HTTP real-time)
MSG Encoding: UTF-8 message encoding
Context Tabsysuser00:
HTTP Header: SOAPAction: http://xmlns.oracle.com/ouaf/multispeak_​3.0/ <OPERATION>
HTTP Login User: <USER_​ID>
HTTP Login Password: <PASSWORD>
HTTP Method: POST
HTTP URL 1: http:// <EM_​SERVER> : <EM_​SERVER_​PORT> /soa-infra/services/D3/ <SERVICE> / <SERVICE>
where:
<OPERATION> : the operation performed by the message sender (see Operation column in the table above)
<USER_​ID> : the user ID used to log into WebLogic Enterprise Manager
<PASSWORD> : the password used to log into WebLogic Enterprise Manager
<EM_​SERVER_​IP> : the machine name or IP address of server where the WebLogic Enterprise Manager is installed
<EM_​SERVER_​PORT> : the port where the WebLogic Enterprise Manager is installed
<SERVICE> : the service invoked by the message sender (see Service column in the table above)