SRS Rules
The following SRS Rules must be configured when using the FLEX SCADA module:
scadaFepInterface
Defines the SCADA interface to use. Currently only supports one interface.
This must be set to LecInterface
scadaFepTlsCert
If encrypted communication is being deployed then this SRS must be set and defines the path or ID of the TLS Certificate for encrypting communication between NMS and the Front End Processor.
RT_IGNORE_TIMESTAMP
Defines whether changes with older timestamps should be discarded. If set to Yes then the changes will not be discarded.
This rule must be set to Yes
nmsScadaEnabled
Controls whether the FLEX SCADA module is enabled or not.
This rule must be set to Yes
NMSAlarmsAllowMainAlarmListClosure
Controls whether the main alarm list can be closed once displayed. The main alarm list will be identifiable from the title bar.
This rule must be set to Yes or No to allow or disallow closure of the main alarm list respectively.
NMSAlarmsDisplayUponNewUnackAlarm
Controls whether the main alarm list automatically receives focus when a new unacknowledged alarm is raised.
This rule must be set to Yes to automatically move focus to the main alarm list or No to leave the current window focus unchanged.