5.21.1 Configuring Data Source in WebLogic Application Server
If the ENABLE_PARALLEL_WS_CALL and ENABLE_PARALLEL_WS_TAGS_CALL parameter values are Y in the SETUP_RT_PARAMS table, it is recommended to perform the following configuration in Weblogic Application Server to avoid retrigger failure.
- Open WebLogic Application Server. For more information, see Oracle Financial ServicesSanctions Pack Installation and Configuration Guide.
- From the LHS menu (Domain Structure), click Services Data Sources. The Summary of JDBC Data Sources window is displayed.
- Select SANCINFO from the Data Sources table. The Settings for SANCINFO window is displayed.
- Select the Connection Pool tab.
- Click Advanced. The Advanced informations are displayed.
- Click and select the Test Connections On Reserve Check box and enter the value as SQL IS VALID in Test Table Name.
- Click Save.