Power Management State Changes
The following table describes the scenarios in which the power management state changes for the Express Station 4 Series.
Table 5-1 Power Management State Changes
| Starting State | Event | Resulting State | 
|---|---|---|
| Unplugged | AC power is connected to a wall outlet and the last recorded power state was not the ON state. | NOPOWER | 
| NOPOWER | The operator presses the power button for less than 1 second. | ON | 
| NOPOWER | The operator presses the power button for more than 4 seconds. | ON | 
| NOPOWER | A server application sends a Wake On LAN command. | ON | 
| NOPOWER | AC power fails and then is restored. | NOPOWER* | 
| ON | The operator presses the power button for less than 1 second. | NOPOWER** | 
| ON | The application shuts down the Express Station. | NOPOWER | 
| ON | The Client Application Loader sends a Restart command. | NOPOWER and then ON | 
| ON | AC power fails and then is restored. | ON* | 
*Based on the default BIOS power settings.
**Microsoft Windows: Pressing the power button begins a graceful shutdown. This behavior is based on the Windows power button management setting. Oracle Linux for MICROS: Pressing the power button initiates a graceful shutdown, but shutdown may take up to 10 seconds to complete.
Parent topic: Power Management States