Property Ports

Starting with Simphony 19.6, a Secure Port column is now available from the Simphony EMC modules listed below. ServiceHosts now listen on separate HTTP and HTTPS ports for peer communications.

Access the EMC and then navigate to each module by selecting the following:

  • Location, Setup, Property Parameters, Workstations tab

  • Location, Setup, Workstations, Service Host tab

  • Location, Setup, KDS Controllers, Service Host tab

  • Location, Setup, KDS Controllers, Backup Service Host tab

  • Enterprise, Setup, Service Hosts module

  • Enterprise, Setup, Interfaces module

The Secure Port number column is non-configurable by design. You should expect (and allow) increased network traffic from any ServiceHosts assigned to these secure ports.

Table 4-2 Property Ports

Service Port Number Configurable?

ServiceHost version 2

HTTP: 8080

HTTPS: 8087

Only HTTP is configurable

ServiceHost as a Service (no Ops)

HTTP: 8071

HTTPS: 8087

Only HTTP is configurable

Print Controller

HTTP: 8080

HTTPS: 8087

Only HTTP is configurable

IP Printer Listening

HTTP: 9100

Yes

Banquet Printing

HTTP: 9100

Yes

KDS Client (Display)

HTTP: 5022

Yes

KDS Controller Service

HTTP: 5023

Yes

KDS Backup Controller Service

HTTP: 5031

Yes

Client Application Loader (server selection screen)

TCP 7300

No

Client Application Loader (property selection screen)

HTTP: 8080

Yes

NetTCPRelayBinding (TMS/Azure)

TCP: 9350, 9351, 9352

No

NetTCPRelayBinding (TMS/Azure)

HTTP: 80

No

Note:

Workstations running Oracle Linux for MICROS are preconfigured with firewall rules, and available ports are limited. If this feature is needed, then the firewall rules must be manually adjusted.