Configure Axway B2Bi for Binary File Transmission

  1. Log in to a client computer.
  2. From the browser, go to (Sender or Receiver): http://<AxwayB2BiServer>:6080/ui.
  3. In the Axway B2Bi Login screen, enter the Axway B2Bi User ID and Password, and click Login.
  4. In the Getting Started screen, hover over the Trading Configuration icon and from the drop-down menu, select Recent Communities > <community>.
  5. In the Summary screen, click the Application Pickup icon and add an application pickup.
  6. In the Choose transport protocol screen, click File system option and click Next.
  7. In the From address and To address screens, click Next.

    Address must be determined by either message attribute configuration or by protocol address only.

  8. In the Configure the file system settings screen, on the Sender's Axway B2Bi Server, locate Common/Out folder and create the following folder structure: Common\Out\Sender's Routing ID\Receiver's Routing ID
  9. In the Exchange Name screen, enter the Exchange Name and click Finish.
  10. In the Change this application pickup exchange screen, click the Message attributes tab.
  11. In the Message attribute directory mapping tab:
    1. The system moves them to the Selected attributes list.
    2. Select From routing ID and To routing ID and click Add.
    3. Locate the Available Attributes list.
    4. Click the From address tab.
  12. Click To address tab, select the Address determined by message attribute configuration option or by protocol address only and click Save Changes.
  13. On the Sender's Axway B2Bi Server, locate Common/Out folder and create the following folder structure: Common\Out\Sender's Routing ID\Receiver's Routing ID

    Note:

    This completes the folder configuration for outgoing binary transmissions. Since binary file transmission configuration is based on these folder names, each combination of Sender and Receiver Routing ID must be unique for binary file transmission to different trading partners.

    The Binary file should be dropped in the RECEIVER's Routing ID Folder which is the last folder. Although in the Axway B2Bi GUI the Application Pickup folder will show up only ..\common\out.

For incoming binary transmissions, repeat steps 5 - 8 for Application Delivery.

Repeat steps 1 - 12 for setting up the Receiver Axway B2Bi.