Mapping considerations—InForm application to Clintrial software
InForm metadata objects correlate to Clintrial metadata objects..
Mapping definitions specify how InForm metadata objects correlate to Clintrial metadata objects. The following table describes considerations to be aware of when mapping metadata from an InForm trial to a Clintrial protocol in a hybrid trial.
InForm metadata |
Considerations |
---|---|
Association |
Associations between forms have no direct corollary in the Clintrial software. |
Checkbox group |
Maps to a single item for each check box and one additional item for each Other field associated with a check box. |
Date field |
The following options are available for mapping date fields:
|
Design note |
In the InForm Architect application, the definition of any type of trial component can include design notes. These design notes are not translated to the Clintrial protocol. However, when generating mappings for InForm items, the mapping generator populates the Design Note property of the CTITEM mapping definition with the text of the Question property of the item. This value is inserted into the Description field for the Clintrial item. |
Form |
Maps to a:
|
Item |
Maps to a Clintrial item. To mark an item as required, you must set the Item Required property for the item in the InForm Architect application. |
Item question |
Maps to a field label (hybrid trial only; metadata element may not be defined in an EDC-only trial). |
Itemset |
Each item within an itemset maps to a single item within the panel. Itemsets in the InForm Architect application derived from page sections in a Clintrial protocol correspond to repeating items in the Clintrial software (page section with the Has Repeats attribute set). |
Pulldown control |
Maps to a single item within the panel. The item stores the string value associated with the pulldown control. |
Radio button |
Maps to a single item within the panel. The item stores the numeric value associated with the radio group. The mapping generator automatically calculates the maximum string length of each radio group control. |
Radio group/Pulldown consisting of a group of radio buttons or a drop down list and one or more Other fields. |
Maps to one item representing the radio group or pulldown list and an additional number of items representing the Other fields. |
Repeating form |
Corresponds to a single panel with items. The FormIndex value in the Clintrial database table holds form instance information (numeric value). A repeating form in the InForm Architect application derived from a page template in a Clintrial protocol corresponds to a page template with the Has Repeats attribute set. |
Repeating visit |
Single panels, that comprise forms within visit, contain a VisitIndex value. The Clintrial database table (panel) holds visit instance information (numeric value). |
Required item |
Items marked as required in the InForm Architect application do not translate to required items in the Clintrial software. To force an item to be required in the Clintrial software, set the Item Required property for the item to True in a mapping definition. |
Rule |
Corresponds to a rule or derivation in the Clintrial software. Rules are maintained separately in the InForm application and the Clintrial software, but the rules created in each application can affect data in the other:
|
Section |
Page section (panels Types 1, 2, 3, 4). Hybrid trial only, metadata element may not be defined in an EDC-only trial. |
Study version |
Corresponds to a study book (hybrid trial only; metadata element may not be defined in an EDC-only trial). |
Study (Trial) |
Corresponds to a protocol (Type 1 - or clinical data protocols - only). |
Unit |