Previous Topic

Next Topic

Book Contents

Location of LSID components in ODM extract files

LSID component

Location in ODM

Notes

Trial

Alias used to register the study with the InForm Adapter software.

 

Site ID

AdminData/Location/@OID

 

Subject GUID

ClinicalData/SubjectData/@GUID

 

Visit name

ClinicalData/SubjectData/StudyEventData/@StudyEventOID

 

Visit revision

StudyEventDef/@Revision

The revision of the visit in the study version for which the item has data. This value must be looked up in the metadata.

Visit index

ClinicalData/SubjectData/StudyEventData/@StudyEventRepeatKey

If this attribute is not present, pass the value 1; note that you do not need ".000."

Form name

ClinicalData/SubjectData/StudyEventData/FormData/@FormOID

 

Form revision

FormDef/@Revision

The revision of the form in the study version for which the item has data. This value must be looked up in the metadata.

Form index

ClinicalData/SubjectData/StudyEventData/FormData/@FormRepeatKey

If this attribute is not present, pass the value 1; note that you do not need ".000."

Section name

ItemGroupDef/@Name

Get the ItemGroupOID and look up the name in the metadata for that study version.

Itemset name

ItemGroupDef/@ItemSetRefName

Required only if the item exists in an itemset.