Get a list of devices

get

/Device

Retrieves a list of devices that meet supplied query parameters

Note: The Device.status modifier element is not supported and not returned.

Request

Query Parameters
  • The logical resource ID associated with the device. This parameter is required if patient is not used.
    Example: 7890
  • The patient to whom the device is affixed. This parameter is required if _id is not used.
    Example: 12345
Header Parameters
Back to Top

Response

Supported Media Types

Default Response

This operation supports the following authorization types:
  • Provider
  • Patient
  • System
Example Request:
https://fhir-open.cerner.com/dstu2/ec2458f2-1e24-41c8-b71b-0e701af7583d/Device?patient=12724066
Example Response:
{
  "resourceType": "Bundle",
  "id": "584907b7-4229-4186-8db3-ad48a4b89600",
  "type": "searchset",
  "total": 1,
  "link": [
    {
      "relation": "self",
      "url": "https://fhir-open.cerner.com/dstu2/ec2458f2-1e24-41c8-b71b-0e701af7583d/Device?patient=12724066"
    }
  ],
  "entry": [
    {
      "fullUrl": "https://fhir-open.cerner.com/dstu2/ec2458f2-1e24-41c8-b71b-0e701af7583d/Device/31539245",
      "resource": {
        "resourceType": "Device",
        "id": "31539245",
        "meta": {
          "versionId": "1",
          "lastUpdated": "2020-07-06T23:58:35.000Z"
        },
        "text": {
          "status": "generated",
          "div": "<div><p><b>Device</b></p><p><b>Patient</b>: SMART, NANCY</p><p><b>Type</b>: Pacemaker</p><p><b>Manufacturer</b>: Pacemaker Plus</p><p><b>Manufacture Date</b>: Jan  9, 2017 12:00 P.M. UTC</p><p><b>Model</b>: T0765</p><p><b>Serial Number</b>: 17642857292</p><p><b>Lot Number</b>: 7723</p><p><b>Owner</b>: Model Clinic</p><p><b>UDI</b>: 1721123408</p></div>"
        },
        "identifier": [
          {
            "type": {
              "coding": [
                {
                  "system": "https://hl7.org/fhir/identifier-type",
                  "code": "SNO",
                  "display": "Serial Number"
                }
              ],
              "text": "Serial Number"
            },
            "value": "17642857292"
          }
        ],
        "type": {
          "text": "Pacemaker"
        },
        "manufacturer": "Pacemaker Plus",
        "model": "T0765",
        "manufactureDate": "2017-01-09T12:00:00.000Z",
        "expiry": "2040-07-02T10:00:00.000Z",
        "udi": "1721123408",
        "lotNumber": "7723",
        "owner": {
          "display": "Model Clinic"
        },
        "patient": {
          "reference": "Patient/12724066",
          "display": "SMART, NANCY"
        }
      }
    }
  ]
}
Headers
  • Unique Oracle-assigned identifier for the request. If you need to contact Oracle about a particular request, provide the X-Request-Id, if present.
  • Unique Oracle-assigned identifier for the request. If you need to contact Oracle about a particular request, provide the opc-Request-Id, if present.

x-read-by-ids Response

Example Request:
"https://fhir-open.cerner.com/dstu2/ec2458f2-1e24-41c8-b71b-0e701af7583d/Device?_id=31539245"
Example Response:
{
    "resourceType": "Bundle",
    "id": "292c3a58-7148-4fae-8971-a7a5568cb3d6",
    "type": "searchset",
    "total": 1,
    "link": [
      {
        "relation": "self",
        "url": "https://fhir-open.cerner.com/dstu2/ec2458f2-1e24-41c8-b71b-0e701af7583d/Device?_id=31539245"
      }
    ],
    "entry": [
      {
        "fullUrl": "https://fhir-open.cerner.com/dstu2/ec2458f2-1e24-41c8-b71b-0e701af7583d/Device/31539245",
        "resource": {
          "resourceType": "Device",
          "id": "31539245",
          "meta": {
            "versionId": "1",
            "lastUpdated": "2020-07-06T23:58:35.000Z"
          },
          "text": {
            "status": "generated",
            "div": "<div><p><b>Device</b></p><p><b>Patient</b>: SMART, NANCY</p><p><b>Type</b>: Pacemaker</p><p><b>Manufacturer</b>: Pacemaker Plus</p><p><b>Manufacture Date</b>: Jan  9, 2017 12:00 P.M. UTC</p><p><b>Model</b>: T0765</p><p><b>Serial Number</b>: 17642857292</p><p><b>Lot Number</b>: 7723</p><p><b>Owner</b>: Model Clinic</p><p><b>UDI</b>: 1721123408</p></div>"
          },
          "identifier": [
            {
              "type": {
                "coding": [
                  {
                    "system": "https://hl7.org/fhir/identifier-type",
                    "code": "SNO",
                    "display": "Serial Number"
                  }
                ],
                "text": "Serial Number"
              },
              "value": "17642857292"
            }
          ],
          "type": {
            "text": "Pacemaker"
          },
          "manufacturer": "Pacemaker Plus",
          "model": "T0765",
          "manufactureDate": "2017-01-09T12:00:00.000Z",
          "expiry": "2040-07-02T10:00:00.000Z",
          "udi": "1721123408",
          "lotNumber": "7723",
          "owner": {
            "display": "Model Clinic"
          },
          "patient": {
            "reference": "Patient/12724066",
            "display": "SMART, NANCY"
          }
        }
      }
    ]
  }
Headers
  • Unique Oracle-assigned identifier for the request. If you need to contact Oracle about a particular request, provide the X-Request-Id, if present.
  • Unique Oracle-assigned identifier for the request. If you need to contact Oracle about a particular request, provide the opc-Request-Id, if present.
Back to Top