Source XML Received for the Case

Once Oracle Argus Safety accepts a case as an initial or follow-up case, the system attaches the source XML (ICSR) and the Initial Selection PDF to the case in the Additional Info tab as follows:

  • Initial/Follow-up Source XML
    • Attachment Classification &endash - As specified in the Reporting Destination for XML Source Classification.
    • Date &endash - The system date when the user accepted the case for XML.
    • Description &endash - The acceptance notes entered by the user for XML.
    • When the user clicks the Source ICSR, the system permits the user to view the ICSR by opening the ICSR Viewer (E2B Viewer).
  • Initial Selection PDF
    • Attachment Classification - As specified in the Reporting Destination for Selection Source Classification.
    • Date - The system date when you accepted the case for XML.
    • Description - The acceptance notes you entered for XML.
  • Follow-up Source XML
    • When you click the Source ICSR PDF or the E2B Difference Report, the system enables you to view the Initial Selection PDF or the E2B Difference Report in a different IE window.
  • When you accept the case as an initial or follow-up ICSR, the system inserts the case number before Business Level Acknowledgement Notes in the following format: Imported Case #: xxxx
  • If the system receives the ICSR via the physical gateway, it sends a low level ACK to indicate that the file was reviewed by Oracle Argus Interchange Services.
    • The system places the file in the Physical Out folders as defined in the reporting destination configured in the E2B Mapping.
    • When the system receives files from EDI, the system continues to let the EDI Gateway send the low level ACK.
    • The Oracle Argus Interchange Services does not process the Low Level ACK in the Physical In destination folder but enters any errors in the log file because the file will always be rejected by the Oracle Argus Interchange Service.