Incorrect TESTUNIT UCUM code in the FAERS E2B(R3) report

Summary

FAERS R3 TESTUNIT UCUM code is incorrect for (MILLIGRAM PER DECILITRE) value in the CFG_M2 table (Bug 39550351).

Before

When you selected the coded value mg/dL – MILLIGRAM PER DECILITRE in the Case Form > Patient > Lab Data > Result Unit, the FAERS E2B(R3) report incorrectly populated the free-text field TESTRESULTTEXT[F.r.3.4] instead of the structured field TESTUNIT[F.r.3.3]. This issue occurred due to incorrect factory configuration in allowed values, where the UCUM code was defined as mg/dl instead of the correct value mg/dL.

After

The factory configuration in allowed values is corrected to mg/dL, resulting in proper mapping and correct population of the TESTUNIT[F.r.3.3] field in the FAERS E2B(R3) report.

Impacted module

E2B(R3) export (FAERS)

Ported from

8.4.4.6