Billable Charge Read Details Upload Staging Layout

You must create a billable charge read details upload record for each read detail to be uploaded. The name of this table is CI_BCHG_UP_READ. The following table describes each column on this table. Refer to "pass through" charges for more information about how this type of information is used.

Column Name

Length

Req'd

Data Type

Comments

BCHG_UP_ID

30

Y

Char

This is the foreign key to the billable charge upload staging record.

SP_ID

10

Y

Char

Note, if USAGE_FLG is calculation, you can set this field to 0 if you do not know the SP ID. The only thing that's important is that the combination of BCHG_UP_ID, SP_ID and SEQNO are unique.

SEQNO

5

Y

Number

This should be a value greater than zero. See SP_ID comment for more information. This is typically the sequence number of the register on the meter.

END_READ_DTTM

26

Y

DateTime

This is the date and time of the end read

END_REG_READ_ID

12

N

Char

This field must reference an existing register read ID if USAGE_FLG is anything other than a calculation.

END_REG_READING

9.6

Y

Number

This is the reading of the end read.

FINAL_REG_QTY

12.6

Y

Number

This is the final amount of the reading (this is the amount of billable consumption the read detail contributed to the entire billed consumption).

FINAL_SQI

8

N

Char

The service quantity identifier of the FINAL_REG_QTY. If specified, it must reference a valid value on CI_SQI. Note, at least one of the following fields should be specified: FINAL_SQI, FINAL_UOM_CD.

FINAL_TOU_CD

8

N

Char

The time-of-use code of the FINAL_REG_QTY. If specified, it must reference a valid value on CI_TOU.

FINAL_UOM_CD

4

N

Char

The unit of measure of the FINAL_REG_QTY. If specified, it must reference a valid value on CI_UOM. Note, at least one of the following fields should be specified: FINAL_SQI, FINAL_UOM_CD.

HOW_TO_USE_FLG

2

Y

Char

See the field description for valid values (CI_BCHG_UP_READ).

MSR_PEAK_QTY_SW

1

Y

Char

Y or N

MSR_QTY

12.6

Y

Number

This is the difference between END_REG_READING and START_REG_READING for subtractive registers.

REG_CONST

6.6

Y

Number

This is the register's constant (the value used to adjust the measured quantity due to something associated with the physical meter). Set this to a value of 1 if it is not known.

SQI_CD

30

N

Varchar

The service quantity identifier of END_REG_READING and START_REG_READING. If specified, it must reference a valid value on CI_SQI. Note, at least one of the following fields should be specified: SQI_CD, TOU_CD, UOM_CD.

START_READ_DTTM

26

Y

DateTime

This is the date and time of the start reading.

START_REG_READ_ID

12

Y

Char

This field must reference an existing register read ID if USAGE_FLG is anything other than a calculation.

START_REG_READING

9.6

Y

Number

This is the reading of the start read.

TOU_CD

30

N

Char

The time-of-use code of END_REG_READING and START_REG_READING. If specified, it must reference a valid value on CI_TOU.

UOM_CD

30

Y

Char

The unit of measure of END_REG_READING and START_REG_READING.

USAGE_FLG

2

Y

Char

See the field description for valid values (CI_BCHG_UP_READ).

USE_PCT

3

Y

Number

This is the percentage of the consumption that was billed (this will typically be 100).