External System

External systems represent external applications with which the Smart Grid Gateway will exchange messages or data. In the case of the Smart Grid Gateway adapters, external systems represent the head-end systems with which the adapters communicate.

An external system that represents the Itron OpenWay head end must be present in your system. If this is not present in your configuration, add it, along with the following Outbound Message Types. Refer to the Oracle Utilities Application Framework documentation for more information about creating external systems.

External System - Itron OpenWay:

  • External System: Itron OpenWay

  • Description: Itron OpenWay

  • Outbound Message Types:

Outbound Message Type Message Sender
D8-INTRGRP D8-ITRON_IBG
D8-COMM D8-COMM
D8-DCOMM D8-DCOMM
D8-DSC

Message sender associated with the Device Status Check Outbound Message Type

D8-DSCMD

Message sender associated with the Device Status Check Multi Device Outbound Message Type

D8-DLSV D8-DLSV
D8-RCONN D8-RCONN
D8-RDCONN D8-RDCONN
D8-RDSS D8-RDSS

Note: The following apply to all of the above outbound message types:

  • Processing Method: Real-time

  • Message XSL: D8-Request xsl

  • Response XSL: D8-Response.xsl