APPLY_PARALLELISM | MAX_APPLY_PARALLELISM | MIN_APPLY_PARALLELISM
Valid For
Parallel Replicat
Description
Parallel Replicat has two forms of operation. It can run with a constant number of
                applier threads or it can dynamically adjust the number of appliers based on the
                transaction mix. These parameters control this behavior. You can adjust this
                behavior to increase or decrease the number of apply threads and the initial number
                of connections using the parameters APPLY_PARALLELISM,
                    MAX_APPLY_PARALLELISM, and
                    MIN_APPLY_PARALLELISM.
                  
If these parameters are not set, then the default behavior of Parallel Replicat is to
                use exactly four appliers to apply the changes to the target database.
                    APPLY_PARALLELISM controls the number of applier processes. If
                    APPLY_PARALLELISM is set, the number of appliers will not
                dynamically increase or decrease based on transaction mix. If
                    APPLY_PARALLELISM is set, there can be times where the number
                of concurrent transactions that can be applied by the Parallel Replicat is below the
                number of applier threads, which can result in idle applier threads.
                  
MAX_APPLY_PARALLELISM and
                    MIN_APPLY_PARALLELISM are used in conjunction when you want to
                allow the Parallel Replicat process to dynamically adjust the number of applier
                threads based on the transaction mix. You can set a minimum
                    (MIN_APPLY_PARALLELISM) and maximum
                    (MAX_APPLY_PARALLELISM) number of applier threads to define the
                ranges in which the Replicat automatically adjusts its parallelism. The initial
                number of connections will be in the middle of the two parameter values.
                  
APPLY_PARALLELISM is mutually exclusive with
                    MAX_APPLY_PARALLELISM and
                    MIN_APPLY_PARALLELISM. If
                    MAX_APPLY_PARALLELISM and
                    MIN_APPLY_PARALLELISM are used, then do not set
                    APPY_PARALLELSIM. If APPLY_PARALLELISM is set,
                then do not use MAX_APPLY_PARALLELISM and
                    MIN_APPLY_PARALLELISM.
                  
See Basic Parameters for Parallel Replicat in Using Oracle GoldenGate for Oracle Database.
Syntax
APPLY_PARALLELISM value MIN_APPLY_PARALLELISM value MAX_APPLY_PARALLELISM value
Example
APPLY_PARALLELISM 4
MIN_APPLY_PARALLELISM 2     
                  
 MAX_APPLY_PARALLELISM 10