Oracle GoldenGate Error Messages

OGG-02149

Standby database has made no progress for more than {0} seconds.


Cause

Extract is abending because the Active Standby Database has not been applying redo changes from the source database and has reached its timeout threshold.


Action

Correct the problem on the Active Data Guard standby database or increase the Extract timeout threshold by setting parameter DBOPTIONS FETCHTIMEOUT if using Integrated Capture or TRANLOGOPTIONS ADGTIMEOUT if using Classic Extract.