- Oracle ILOM Protocol Management Reference SNMP and IPMI Firmware Release 5.0.x
- Server Management Using IPMI
- Performing System Management Tasks (IPMItool)
- View Single Sensor Details
View Single Sensor Details
-
To view details about a single sensor on a managed device, type:
sensor get /target/sensor_name
For example, to view sensor details about the system temperature (
/SYS/T_AMB
), you would type:$ ipmitool -I [orcltls|lanplus] -H SP_hostname_or_IPaddress -U
username -P password
sensor get /SYS/T_AMB
Note:
The IPMI TLS interface (orcltls
) is supported as of Oracle ILOM firmware version 3.2.8 and later. For a higher level of security, you should always specify the IPMI TLS interface (-I orcltls
) when executing Oracle ILOM commands from the IMPItool utility. For more information about using the IPMI TLS interface from Oracle, see these topics:IPMI TLS Service and Interface and Configure IPMI Management Access for Increased Security.The output might look like the following:
Locating sensor record... Sensor ID : /SYS/T_AMB (0x8) Entity ID : 41.0 Sensor Type (Analog) : Temperature Sensor Reading : 24 (+/- 0) degrees C Status : ok Lower Non-Recoverable : 0.000 Lower Critical : 4.000 Lower Non-Critical : 10.000 Upper Non-Critical : 35.000 Upper Critical : 40.000 Upper Non-Recoverable : 45.000 Assertions Enabled : lnc- lcr- lnr- unc+ ucr+ unr+ Deassertions Enabled : lnc- lcr- lnr- unc+ ucr+ unr+