Table 8-19 DCU Auto and Manual Failover Properties
System Failover Property | Definition |
---|---|
Auto | Automated failover by Oracle ILOM for DCUs is enabled. |
Manual | Automated failover by Oracle ILOM for DCUs is
disabled.
Note: When the Failover property is set to Manual, Oracle ILOM is prevented from performing system initiated DCUs failover. Automated failover of the Active-SP is always enabled. For M7-4 and M8-4 systems, the Active-SP is also the controlling SP for DCU0, therefore, DCU0 failover might still occur in the context of an Active-SP failover (typically initiated by component health). When Failover is set to Manual, Oracle ILOM will automatically log the following event in cases when a DCU failover attempt would have been made if the Failover property was set to Auto: Failover on /System/DCUs/DCU_x was not initiated by system due to auto-failover disabled by user. |