Power Supply (PS) Indicators

Each power supply (PS) has three indicators arranged in a single row from left to right. Power supplies for System A are PS2 and PS3. Power supplies for System B are PS0 and PS1.


Callouts for power supply (PS) indicator panel picture.
Call Out Status LED or Button Icon and Color Description

1

Locate button/LED

Fault-Service Required


Service Action Required LED icon

Locate Button/LED icon

Amber

Indicates the location of the power supply in the server:

  • Off – Power supply is operating normally,

  • Fast blink – Use Oracle ILOM to activate this LED to enable you to locate a power supply quickly and easily.

  • Steady On –Lights steady on when the power supply is in a fault state.

2

OK

Power Supply OK LED


OK LED icon

Green

Indicates the functional state of the power supply:

  • Off – PS is disconnected.

  • Steady On – PS is powered on and functionaing normally. When this LED is lit, the AC OK LED is also lit.

Note: Oracle ILOM signals a fault on any installed power supply that is not connected to an AC power source, since it might indicate a loss of redundancy.

3

AC OK LED

Input ~AC

Green

Indicates the operational state of the power supply:

  • Off – PS is not connected to an AC power source.

  • Steady On – PS is connected to a properly rated AC power source.