System Sensor NAC Names

This section includes information for system sensors:

Name (1x8) System A Name (2x4-A Side) System B Name (2x4-B Side) Description

/SYS/ACPI

/SYS/ACPI

/SYS/ACPI

Discrete Host power state (hidden)

01h: host is on.

20h: host is off.

/SYS/PS_REDUNDANCY

/SYS/PS_REDUNDANCY

/SYS/PS_REDUNDANCY

Discrete PS Redundancy status

00h: fully redundant

02h: degraded redundancy

03h: non-redundant

05h: insufficient power

/SYS/VPS

/SYS/VPS

/SYS/VPS

Threshold Chassis power consumption sensor Watts

/SYS/VPS_MEMORY

/SYS/VPS_MEMORY

/SYS/VPS_MEMORY

Threshold Memory power consumption Watts

/SYS/VPS_FANS

/SYS/VPS_FANS

/SYS/VPS_FANS

Threshold Fan power consumption Watts

/SYS/T_AMB

/SYS/T_AMB

/SYS/T_AMB

Threshold Chassis ambient temperature Degree in C

/SYS/HOST_ERR

/SYS/HOST_ERR

/SYS/HOST_ERR

Discrete Host fault sensor

01h: No Fault

02h: Fault

/SYS/FM[0-7]/PRSNT

/SYS/FM[0-3]/PRSNT

/SYS/FM[4-7]/PRSNT

Discrete Fan module presence

01h: Absent

02h: Present

/SYS/FM[0-7]/F[0/1]/TACH

/SYS/FM[0-3]/F[0/1]/TACHThreshold

/SYS/FM[4-7]/F[0/1]/TACH

Fan speed. RPM

/SYS/DPCC[0-7]/PRSNT

/SYS/DPCC[0-3]/PRSNT

/SYS/DPCC[4-7]/PRSNT

Discrete DPCC Carrier presence.

01h: Absent

02h: Present

/SYS/DPCC[0-7]/PRSNT

/SYS/DPCC[0-3]/PRSNT

/SYS/DPCC[4-7]/PRSNT

Discrete DPCC Carrier presence.

01h: Absent

02h: Present

/SYS/DPCC[0-7]/PCIE[1-16]/PRSNT

/SYS/DPCC[0-3]/PCIE[1-8]/PRSNT

/SYS/DPCC[4-7]/PCIE[9-16]/PRSNT

Discrete PCIE card presence.

01h: Absent

02h: Present

/SYS/CMOD[0-7]/P[0-7]/PRSNT

/SYS/CMOD[0-3]/P[0-3]/PRSNT

/SYS/CMOD[4-7]/P[4-7]/PRSNT

Discrete Processor presence.

01h: Absent

02h: Present

/SYS/CMOD[0-7]/PRSNT

/SYS/CMOD[0-3]/PRSNT

/SYS/CMOD[4-7]/PRSNT

Discrete CPU module motherboard presence.

01h: Absent

02h: Present

/SYS/CMOD[0-7]/P[0-7]/D[0-11]/PRSNT

/SYS/CMOD[0-3]/P[0-3]/D[0-11]/PRSNT

/SYS/CMOD[4-7]/P[4-7]/D[0-11]/PRSNT

Discrete DIMM presence (hidden)

01h: Absent

02h: Present

/SYS/CMOD[0-7]/T_IN

/SYS/CMOD[0-3]/T_IN

/SYS/CMOD[4-7]/T_IN

Threshold CMOD inlet ambient temperature Degree in C

/SYS/CMOD[0-7]/T_IN_DPCC

/SYS/CMOD[0-3]/T_IN_DPCC

/SYS/CMOD[4-7]/T_IN_DPCC

Threshold Inlet air temperature to the DPCC connector. Degree in C

/SYS/CMOD[0-7]/T_IN_HDD

/SYS/CMOD[0-3]/T_IN_HDD

/SYS/CMOD[4-7]/T_IN_HDD

Threshold Inlet air temperature to the HDD Disk Riser. Degree in C

/SYS/CMOD[0-7]/T_OUT_CPU

/SYS/CMOD[0-3]/T_OUT_CPU

/SYS/CMOD[4-7]/T_OUT_CPU

Threshold CMOD temperature behind CPU Degree in C

/SYS/SMOD[0-1]/MB/T_IN

/SYS/SMOD0/MB/T_IN

/SYS/SMOD1/MB/T_IN

Threshold SMOD Inlet air temperature near midplane connectors. Degree in C

/SYS/SMOD[0-1]/MB/T_HBA

/SYS/SMOD0/MB/T_HBA

/SYS/SMOD1/MB/T_HBA

Threshold SMOD temperature on bottomside HBA location. Degree in C

/SYS/SMOD[0-1]/MB/T_PHY

/SYS/SMOD0/MB/T_PHY

/SYS/SMOD1/MB/T_PHY

Threshold SMOD temperature on topside network PHY chip. Degree in C

/SYS/SMOD[0-1]/MB/T_OUT

/SYS/SMOD0/MB/T_OUT

/SYS/SMOD1/MB/T_OUT

Threshold SMOD temperature on topside rear outlet. Degree in C

/SYS/PS[0-3]/PRSNT

/SYS/PS[2-3]/PRSNT

/SYS/PS[0-1]/PRSNT

Discrete Power supply presence

01h: Absent

02h: Present

/SYS/PS[0-3]/P_IN/

SYS/PS[2-3]/P_IN

/SYS/PS[0-1]/P_IN

Threshold PS input power consumption Watts

/SYS/PS[0-3]/P_OUT

/SYS/PS[2-3]/P_OUT

/SYS/PS[0-1]/P_OUT

Threshold PS output power Watts

/SYS/PS[0-3]/STATE

/SYS/PS[2-3]/STATE

/SYS/PS[0-1]/STATE

Discrete IPMI Standard Power Supply Sensor

01h: No Fault

02h: Fault

/SYS/PS[0-3]/T_AMB

/SYS/PS[2-3]/T_AMB

/SYS/PS[0-1]/T_AMB

Threshold PS inlet temperature Volts

/SYS/PS[0-3]/V_12V

/SYS/PS[2-3]/V_12V

/SYS/PS[0-1]/V_12V

Threshold PS main output voltage Volts

/SYS/PS[0-3]/V_12V_STBY

/SYS/PS[2-3]/V_12V_STBY

/SYS/PS[0-1]/V_12V_STBY

Threshold PS standby output voltage Volts

/SYS/PS[0-3]/V_IN

/SYS/PS[2-3]/V_IN

/SYS/PS[0-1]/V_IN

Threshold PS input voltage Volts