System Sensor NAC Names
This section includes information for system sensors:
Name (1x8) | System A Name (2x4-A Side) | System B Name (2x4-B Side) | Description |
---|---|---|---|
/SYS/ACPI |
/SYS/ACPI |
/SYS/ACPI |
Discrete Host power state (hidden) 01h: host is on. 20h: host is off. |
/SYS/PS_REDUNDANCY |
/SYS/PS_REDUNDANCY |
/SYS/PS_REDUNDANCY |
Discrete PS Redundancy status 00h: fully redundant 02h: degraded redundancy 03h: non-redundant 05h: insufficient power |
/SYS/VPS |
/SYS/VPS |
/SYS/VPS |
Threshold Chassis power consumption sensor Watts |
/SYS/VPS_MEMORY |
/SYS/VPS_MEMORY |
/SYS/VPS_MEMORY |
Threshold Memory power consumption Watts |
/SYS/VPS_FANS |
/SYS/VPS_FANS |
/SYS/VPS_FANS |
Threshold Fan power consumption Watts |
/SYS/T_AMB |
/SYS/T_AMB |
/SYS/T_AMB |
Threshold Chassis ambient temperature Degree in C |
/SYS/HOST_ERR |
/SYS/HOST_ERR |
/SYS/HOST_ERR |
Discrete Host fault sensor 01h: No Fault 02h: Fault |
/SYS/FM[0-7]/PRSNT |
/SYS/FM[0-3]/PRSNT |
/SYS/FM[4-7]/PRSNT |
Discrete Fan module presence 01h: Absent 02h: Present |
/SYS/FM[0-7]/F[0/1]/TACH |
/SYS/FM[0-3]/F[0/1]/TACHThreshold |
/SYS/FM[4-7]/F[0/1]/TACH |
Fan speed. RPM |
/SYS/DPCC[0-7]/PRSNT |
/SYS/DPCC[0-3]/PRSNT |
/SYS/DPCC[4-7]/PRSNT |
Discrete DPCC Carrier presence. 01h: Absent 02h: Present |
/SYS/DPCC[0-7]/PRSNT |
/SYS/DPCC[0-3]/PRSNT |
/SYS/DPCC[4-7]/PRSNT |
Discrete DPCC Carrier presence. 01h: Absent 02h: Present |
/SYS/DPCC[0-7]/PCIE[1-16]/PRSNT |
/SYS/DPCC[0-3]/PCIE[1-8]/PRSNT |
/SYS/DPCC[4-7]/PCIE[9-16]/PRSNT |
Discrete PCIE card presence. 01h: Absent 02h: Present |
/SYS/CMOD[0-7]/P[0-7]/PRSNT |
/SYS/CMOD[0-3]/P[0-3]/PRSNT |
/SYS/CMOD[4-7]/P[4-7]/PRSNT |
Discrete Processor presence. 01h: Absent 02h: Present |
/SYS/CMOD[0-7]/PRSNT |
/SYS/CMOD[0-3]/PRSNT |
/SYS/CMOD[4-7]/PRSNT |
Discrete CPU module motherboard presence. 01h: Absent 02h: Present |
/SYS/CMOD[0-7]/P[0-7]/D[0-11]/PRSNT |
/SYS/CMOD[0-3]/P[0-3]/D[0-11]/PRSNT |
/SYS/CMOD[4-7]/P[4-7]/D[0-11]/PRSNT |
Discrete DIMM presence (hidden) 01h: Absent 02h: Present |
/SYS/CMOD[0-7]/T_IN |
/SYS/CMOD[0-3]/T_IN |
/SYS/CMOD[4-7]/T_IN |
Threshold CMOD inlet ambient temperature Degree in C |
/SYS/CMOD[0-7]/T_IN_DPCC |
/SYS/CMOD[0-3]/T_IN_DPCC |
/SYS/CMOD[4-7]/T_IN_DPCC |
Threshold Inlet air temperature to the DPCC connector. Degree in C |
/SYS/CMOD[0-7]/T_IN_HDD |
/SYS/CMOD[0-3]/T_IN_HDD |
/SYS/CMOD[4-7]/T_IN_HDD |
Threshold Inlet air temperature to the HDD Disk Riser. Degree in C |
/SYS/CMOD[0-7]/T_OUT_CPU |
/SYS/CMOD[0-3]/T_OUT_CPU |
/SYS/CMOD[4-7]/T_OUT_CPU |
Threshold CMOD temperature behind CPU Degree in C |
/SYS/SMOD[0-1]/MB/T_IN |
/SYS/SMOD0/MB/T_IN |
/SYS/SMOD1/MB/T_IN |
Threshold SMOD Inlet air temperature near midplane connectors. Degree in C |
/SYS/SMOD[0-1]/MB/T_HBA |
/SYS/SMOD0/MB/T_HBA |
/SYS/SMOD1/MB/T_HBA |
Threshold SMOD temperature on bottomside HBA location. Degree in C |
/SYS/SMOD[0-1]/MB/T_PHY |
/SYS/SMOD0/MB/T_PHY |
/SYS/SMOD1/MB/T_PHY |
Threshold SMOD temperature on topside network PHY chip. Degree in C |
/SYS/SMOD[0-1]/MB/T_OUT |
/SYS/SMOD0/MB/T_OUT |
/SYS/SMOD1/MB/T_OUT |
Threshold SMOD temperature on topside rear outlet. Degree in C |
/SYS/PS[0-3]/PRSNT |
/SYS/PS[2-3]/PRSNT |
/SYS/PS[0-1]/PRSNT |
Discrete Power supply presence 01h: Absent 02h: Present |
/SYS/PS[0-3]/P_IN/ |
SYS/PS[2-3]/P_IN |
/SYS/PS[0-1]/P_IN |
Threshold PS input power consumption Watts |
/SYS/PS[0-3]/P_OUT |
/SYS/PS[2-3]/P_OUT |
/SYS/PS[0-1]/P_OUT |
Threshold PS output power Watts |
/SYS/PS[0-3]/STATE |
/SYS/PS[2-3]/STATE |
/SYS/PS[0-1]/STATE |
Discrete IPMI Standard Power Supply Sensor 01h: No Fault 02h: Fault |
/SYS/PS[0-3]/T_AMB |
/SYS/PS[2-3]/T_AMB |
/SYS/PS[0-1]/T_AMB |
Threshold PS inlet temperature Volts |
/SYS/PS[0-3]/V_12V |
/SYS/PS[2-3]/V_12V |
/SYS/PS[0-1]/V_12V |
Threshold PS main output voltage Volts |
/SYS/PS[0-3]/V_12V_STBY |
/SYS/PS[2-3]/V_12V_STBY |
/SYS/PS[0-1]/V_12V_STBY |
Threshold PS standby output voltage Volts |
/SYS/PS[0-3]/V_IN |
/SYS/PS[2-3]/V_IN |
/SYS/PS[0-1]/V_IN |
Threshold PS input voltage Volts |