Environmental Events
The following table lists environmental events.
Messages and Descriptions | Component Name |
---|---|
SNMP Trap: sunHwTrapTempFatalThresholdExceeded Oracle ILOM Event Message: Lower fatal threshold exceeded Severity and Description: Critical; A temperature sensor has reported that its value has gone above an upper fatal threshold setting or below a lower fatal threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold. |
/SYS/PS[0-1]/T_OUT /SYS/PS[0-1]/T_IN /SYS/MB/T_IN_SLOT[1-3] /SYS/MB/T_OUT_SLOT[1-3] |
SNMP Trap: sunHwTrapTempFatalThresholdDeasserted Oracle ILOM Event Message: Lower fatal threshold no longer exceeded Severity and Description: Informational; A temperature sensor has reported that its value has gone below an upper fatal threshold setting or above a lower fatal threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold. |
/SYS/PS[0-1]/T_OUT /SYS/PS[0-1]/T_IN /SYS/MB/T_IN_SLOT[1-3] /SYS/MB/T_OUT_SLOT[1-3] |
SNMP Trap: sunHwTrapTempCritThresholdExceeded Oracle ILOM Event Message: Upper critical threshold exceeded Severity and Description: Critical; A temperature sensor has reported that its value has gone above an upper critical threshold setting or below a lower critical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold. |
/SYS/PS[0-1]/T_OUT /SYS/PS[0-1]/T_IN /SYS/MB/T_IN_SLOT[1-3] /SYS/MB/T_OUT_SLOT[1-3] |
SNMP Trap: sunHwTrapTempCritThresholdDeasserted Oracle ILOM Event Message: Upper critical threshold no longer exceeded Severity and Description: Informational; A temperature sensor has reported that its value has gone below an upper critical threshold setting or above a lower critical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold. |
/SYS/PS[0-1]/T_OUT /SYS/PS[0-1]/T_IN /SYS/MB/T_IN_SLOT[1-3] /SYS/MB/T_OUT_SLOT[1-3] |
SNMP Trap: sunHwTrapTempFatalThresholdExceeded Oracle ILOM Event Message: Lower fatal threshold exceeded Severity and Description: Critical; A temperature sensor has reported that its value has gone above an upper fatal threshold setting or below a lower fatal threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold. |
/SYS/T_AMB |
SNMP Trap: sunHwTrapTempFatalThresholdDeasserted Oracle ILOM Event Message: Lower fatal threshold no longer exceeded Severity and Description: Informational; A temperature sensor has reported that its value has gone below an upper fatal threshold setting or above a lower fatal threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold. |
/SYS/T_AMB |