Always replace a failed power supply with a power supply of the same
type (model).
Remove the replacement power supply from its packaging and place it on an
antistatic mat.
Align the replacement power supply with the empty power supply slot
[1].
Slide the power supply into the bay until it is fully seated [2].
You will hear an audible click when the power supply fully seats.
Reconnect the power cord to the power supply.
Verify that the amber Fault-Service Required LED on the replaced power supply
and the Fault-Service Required LEDs on the front and back panels of the server
are not lit.
Note:
After you have replaced Power
Supply 0, you must reset the Oracle ILOM service processor (SP) to propagate the
key identity properties (KIP) data to the new power supply. For instructions on
resetting the SP, refer to the Oracle ILOM Administrator's Guide
for Configuration and Maintenance Firmware Release 5.1.x at Servers Documentation Systems Management. Power Supply 1
does not contain KIP data, and therefore does not require an SP reset after
replacement.
If you disconnected the two CMA left-side connectors, reconnect the
connectors.
Refer to Install the Cable Management Arm
(Optional) in Oracle Servers X9-2 and X9-2L
Installation Guide