Disk Drive Components

The following table lists the hard disk drive (HDD) and solid state drive (SSD) components.

Component Name (Oracle ILOM CLI Targets) IPMI Type Description Values (if applicable)

/SYS/DBP/HDD[0- x ]

Replaceable component

Hard disk drive

From host

/SYS/DBP/HDD[0- x ]/PRSNT

Discrete sensor

Hard disk drive presence

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/DBP/HDD[0- x ]/STATE

Discrete sensor

Writable multistate, slot/connector sensor type, per IPMI

01h-FAULT_STATUS

02h-IDENTITY

04h-INSTALLED

20h-SLOT_POWER_OFF

/SYS/DBP/HDD[0- x ]/SERVICE

Indicator

Hard disk drive Fault-Service Required LED

Color: Amber

Location: HDD

Off: Normal

On: Hard disk drive was diagnosed as faulty.

/SYS/DBP/HDD[0- x ]/OK2RM

Indicator

Hard disk drive OK to Remove LED

Color: Blue

Location: HDD

Off: Normal

On: Drive is ready to remove.

/SYS/DBP/HDD[0- x ]/NVME

Replaceable component

NVMe drive

/SYS/DBP/HDD[0- x ]/NVME/PRSNT

Discrete sensor

NVMe device presence

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/MB/SSDR[0-1]

Replaceable component

Internal SSD riser (1 on 1U, 2 on 2U)

 

/SYS/MB/SSDR[0-1]/PRSNT

Discrete sensor

Solid-state drive (SSD) riser presence (2 risers on 2U)

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/MB/SSDR[0-1]/SSD[0-1]

Replaceable component

Internal SSD drive

 

/SYS/MB/SSDR[0-1]/SSD[0-1]/PRSNT

Discrete sensor

SSD drive presence (1 SSD per riser on 2U) (Hidden)

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/MB/SSDR[0-1]/SSD[0-1]/STATE

State sensor

SSD drive state

04h-INSTALLED

20h-SLOT POWER OFF

/SYS/MB/SSDR[0-1]/SSD[0-1]/NVME

Replaceable component

Internal SSD that is NVM Express

 

/SYS/MB/SSDR[0-1]/SSD[0-1]/NVME/PRSNT

Discrete sensor

Indicates the SSD is PCIe (NVMExpress)

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

Related Topics: