Export SNMP Connection Settings to a Text File

Export SNMP connection information to a text file to help troubleshoot connection issues or re-enter connection information.

  1. In the left navigation, expand Setup & Administration, then select Library Connections.
  2. At the bottom of the screen, click Export.
    Monitored Libraries section with Export button noted

    The file is saved with the name SnmpConfiguration.txt. Passwords are not included in the file.

Example 6-1 Sample SNMP Configuration File

Define SNMP Client Settings
---------------------------
 
Client Attributes
-----------------
 
STA SNMP Connection Username (Auth) = abc1
Connection Password Encryption (Auth) = Not Specified
Connection Password Encryption (Auth) = SHA
Privacy Encryption Password (Privacy) = Not Specified
Connection Password Encryption (Auth) = DES
STA Engine ID = 0x8000002a050000014817ec1dc1
SNMP Trap Levels = 1,2,3,4,11,13,14,21,25,27,41,45,61,63,65,81,85,100
Trap Community = public
User Community = public
V2C Fallback = false
 
Monitored Libraries
-------------------
 
STA IP Address = 10.80.145.78
Library Name = SL3000A
Library Complex = SL3000_5720123200089
Library Primary IP Address = 10.80.104.51
Library Secondary IP Address = Not Specified
Library Engine ID = 0x80001f880431303030123123303000
Requested MIB Walk Time = 00:00:00
Library Serial Number = 5720123200089
Library Time Zone = UTC
Recent SNMP Trap Communication Status = GOOD
Last Connection Status = SUCCESS
Last Connection Failure Detail = Not Specified